Frame Status Tally Terminal Block; Installing And Removing The Modules; Installing The Module Rear Plates; Table 2-1: Frame Status Tally Terminal Block Pin Assignments - evertz 7800 Manual

3 rack unit frame
Hide thumbs Also See for 7800:
Table of Contents

Advertisement

Each module has a large red LOCAL FAULT LED and a large green MODULE OK LED at the top of the
card edge. This green LED indicates good module health while the red LED indicates that there is a fault
condition on the module. Each module has its own criteria that determines when the red fault LED comes
on. When the red LOCAL FAULT LED is On the module can also assert a fault condition on the Frame
Status bus. On each module there is a jumper that disables sending local card fault information to the
Frame Status Bus. For more information about fault conditions on individual modules, and for the location
of the Frame Status Jumper on the module consult the individual chapter for the module. For example, if
a module requires video or audio for its functionality and the video or audio is not present, the red LOCAL
FAULT LED on the module will be On and the fault will be reported on the frame status bus if the FRAME
STATUS jumper on the module is set to the On position (default).
2.1.

FRAME STATUS TALLY TERMINAL BLOCK

There is a terminal block at the rear of the frame that has a normally open and normally closed relay
contact that can be used to indicate frame status fault conditions to external equipment. There are 4
connections.
Label
G
R
O
C

Table 2-1: Frame Status Tally Terminal Block Pin Assignments

The frame status GROC connector on the 7800FR series frames are a different type
than used on the older 7700 series frames frames to make room for the new
reference BNCs.
The relay contacts can sink up to 1A and operate up to 30 VDC.
3.

INSTALLING AND REMOVING THE MODULES

3.1.

INSTALLING THE MODULE REAR PLATES

Each module is shipped with a matching rear panel plate which houses the connectors appropriate for the
module. When installing a rear plate, locate the desired slot position where you wish to install the rear
plate. Make a note of the slot number where you are installing the rear plate. Orient the plate so that the
labeling is visible when the plate is installed. Loosely fasten the plate to the extrusions using the mounting
screws provided, beginning with the top screw. You will tighten the screws after the main module is
installed.
Pin #
1
Chassis Ground (connect to cable shield)
2
Common (connect to Ground or your reference)
3
Open with respect to common when Frame Status fault exists
4
Closed with respect to common when Frame Status fault exists
Function
Revision 1.3
7800 MultiFrame Manual
7800FR 3 Rack Unit Frame
7800FR - 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

7800fr

Table of Contents