4. Connect each power cord to the server.
5. Connect each power cord to the power source.
6. Power up the server (Power up the server).
Install the secondary PCI riser cage
Procedure
1. Install the riser cage.
2. If needed, install expansion boards.
3. Install the access panel (Install the access panel).
4. Install the server into the rack.
5. Connect each power cord to the server.
6. Connect each power cord to the power source.
7. Power up the server (Power up the server).
Install the access panel
Procedure
1. Place the access panel on top of the server with the latch open.
Allow the panel to extend past the rear of the server approximately 1.25 cm (0.5 in).
2. Push down on the latch.
The access panel slides to a closed position.
3. Tighten the security screw on the latch, if needed.
Operations
38