Installation And Connection - Bosch HGV1F0Y50Z User Manual And Installation Instructions

Free standing cooker
Hide thumbs Also See for HGV1F0Y50Z:
Table of Contents

Advertisement

A gas leak could occur. If you move the appliance after
the gas supply has been established, a gas leak could
occur.
Do not move the appliance once the gas supply is
connected.
If you move the appliance, check that the connec-
tions are not leaking.
For the licensed expert or after-sales service
The settings for configuring your appliance can be
1.
found on the rating plate.
Find out which gas type and which gas pressure
2.
your local gas supply network uses before installing
the appliance, and ensure that the gas setting for
the appliance complies with this information. If the
appliance settings have to be changed, follow the
instructions in the section "Gas connection and con-
version to a different gas type".
This appliance is not connected to a waste gas
3.
main. It must be positioned and connected in ac-
cordance with the applicable installation conditions.
Do not connect the appliance to a waste gas main.
Ensure that suitable ventilation measures are carried
out.
Establish the gas supply using a permanent, non-
4.
elastic connection, such as a gas pipe or a safety
hose.
If you use a safety hose, ensure that the hose is not
5.
trapped or compressed. The hose must not come
into contact with hot surfaces.
6.
The connection must have an easily accessible
locking device.
Flexible hoses
Do not pinch or squeeze hoses.
1.
Do not subject the hoses to twisting or pulling
2.
forces.
Keep the hoses away from sharp edges.
3.
Do not let the hoses come into contact with parts
4.
that may reach a temperature higher than 70 °C
above room temperature.
Ensure that the full length of the hoses can be ac-
5.
cessed for testing.
Checking for leaks
After connecting the gas pipe, use soapy water to
check the connections for leaks.
Starting up
Start up the appliance in accordance with the in-
1.
struction manual.
Ignite all of the burners.
2.
Check the stability of the flames at a high and
low setting.
Moving or transporting the appliance by the gas
pipe (collector) or by the door handle
Do not move the appliance by pulling on the gas
1.
pipe (collector).
a The gas pipe may be damaged and a gas leak may
occur.
Do not move the appliance by holding it by the door
2.
handle.
a This may damage the door hinges and door handle.
For your safety (only for ZA)
This appliance is adjusted to operate on LPG only.
Do not tamper or modify the appliance.
Burn back
¡ Fire in burner tube or chamber.
¡ In the event of a burn-back, where the flame burns
back to the jet, immediately turn the gas supply off
at the control valve on the panel.
¡ After ensuring the flame is extinguished, wait for 1
minute and re-light the appliance in the normal man-
ner.
¡ Should the appliance again burn back, close the
control valve and call a service technician. Do not
use the appliance again until the service technician
has declared that it is safe to do so.
Gas-pressure regulator
¡ This appliance requires an operating pressure of
2,8 kPa at the appliance.
¡ A suitable LPG regulator that complies with the re-
quirements of SANS 1237 must be installed.
Important information for the user:
Note: This appliance may only be installed by a re-
gistered SAQCC Gas installer.
¡ All registered installers are issued with a card carry-
ing their registration number. Ask to be shown the
card before allowing the installation work to com-
mence and make a note of the installer registration
number.
¡ Upon completion of the installation, the installer is
required to explain the operational details of the ap-
pliance together with the safety instructions.
¡ You will be asked to sign acceptance of the installa-
tion and be provided with a completion certificate.
You should only sign for acceptance of the installa-
tion when the installation is completed to your satis-
faction.
¡ Note that your invoice is required in the event that
you wish make a guarantee claim.
Important information for the installer:
¡ This appliance may only be installed by a gas in-
staller registered with the South African qualification
and certification committee (SAQCC).
¡ The appliance must be installed in accordance with
the requirements of SANS 10087-1 for use with
LPG, SANS 827 for use with NG and any fire depart-
ment regulations and/or local bylaws applicable to
the area. If in doubt, check with the relevant author-
ity before undertaking the installation.
¡ Upon completion of the installation you are required
to fully explain and demonstrate to the user the op-
erational details and safety practices applicable to
the appliance and the installation.
Caution
The primary air intake adjuster is set at the factory for
the set gas and must not be reset or tampered with,
this must only be set by an authorized BSH technician.
No modifications to the primary air is allowed to be
done. Please check the rating label for the type of gas
to be used.
4.3 Electrical connection
Only allow a licensed professional to connect the appli-
ance. You must comply with the requirements of your
electricity supplier.
Installation and connection en
9

Advertisement

Table of Contents
loading

Table of Contents