en Installation instructions
21.8 Technical data – Gas
The different types of gas and the corresponding values are listed.
Technical data – Gas
Note the following information for the gas types that are listed in the table for some burners.
Natural gas NG G20/2.0 kPa
Nozzle (mm)
Bypass
1.16
0.78
0.97
0.60
0.72
0.52
1.48
0.94
1.48/0.70
0.92/0.57
1.47
0.76
1.30
-
Liquid gas, butane, propane, G30/mb2.8-3.0 kPa
Nozzle (mm)
Bypass
0.85
0.49
0.65
0.40
0.50
0.32
1.00
0.59
0.95/0.44
0.57/0.30
0.90
0.56
0.85
-
Liquid gas, butane, propane, G30/5.0 kPa
Nozzle (mm)
Bypass
0.75
0.49
0.58
0.40
0.43
0.32
0.80
0.59
0.68/0.43
0.57/0.30
0.88
0.56
0.73
0.55
42
Burner type
High-output burner
Standard-output burner
Economy burner
Wok burner
Dual-flame wok burner
Oven burner
Grill burner
Burner type
High-output burner
Standard-output burner
Economy burner
Wok burner
Dual-flame wok burner
Oven burner
Grill burner
Burner type
High-output burner
Standard-output burner
Economy burner
Wok burner
Dual-flame wok burner
Oven burner
Grill burner
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
4.0
≤ 1.7
4.2
≤ 2.6
4.2
-
3.1
-
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
4.0
≤ 1.7
4.2
≤ 2.6
4.2
-
3.1
-
Power (kW)
Min.
power (kW)
3.0
≤ 1.3
1.75
≤ 0.9
1.0
≤ 0.55
3.4
≤ 1.7
3.4
≤ 2.6
4.4
-
3.1
-
Max. consump-
tion
3
G20 (m
/h)
3
0.285 (m
/h)
3
0.167 (m
/h)
3
0.095 (m
/h)
3
0.381 (m
/h)
3
0.399 (m
/h)
3
0.399 (m
/h)
3
0.295 (m
/h)
Max. consump-
tion
G30 (g/h)
218 (g/h)
127 (g/h)
73 (g/h)
291 (g/h)
306 (g/h)
306 (g/h)
226 (g/h)
Max. consump-
tion
G30 (g/h)
218 (g/h)
127 (g/h)
73 (g/h)
248 (g/h)
248 (g/h)
321 (g/h)
226 (g/h)