Installation And Connection - Bosch HGX5G7W50S User Manual And Installation Instructions

Free standing cooker
Table of Contents

Advertisement

¡ On some appliances, you can connect the gas pipe
to the gas pipe or flexible safety gas hose on the
right-hand or the left-hand side of the appliance. If
necessary, you can change the connection side.
The connection must have a free-standing and eas-
ily accessible locking device.
Target appliance operating pressure
¡ You can find the target operating pressure for your
appliance on the rating plate on the rear of the ap-
pliance.
¡ All the data on your appliance's rating plate relates
to these pressure values.
¡ The manufacturer is not responsible for results, per-
formance or any risk caused by operating the appli-
ance at different values.
WARNING ‒ Risk of explosion!
Escaping gas may cause an explosion. If the gas pres-
sure in your distributing pipes is more than 20% higher
than the values specified on the appliance's rating
plate, a gas leak can occur.
For your own safety, it is imperative that you operate
the appliance with a suitable gas governor.
If you do not know what the gas pressure in your
gas distributing pipes is, please ask your local gas
company.
Connection, maintenance and setting of the gas
governor must be carried out by an authorised in-
stallation specialist.
A gas leak could occur. If you move the appliance after
the gas supply has been established, a gas leak could
occur.
Do not move the appliance once the gas supply is
connected.
If you move the appliance, check that the connec-
tions are not leaking.
For the licensed expert or after-sales service
The settings for configuring your appliance can be
1.
found on the rating plate.
Find out which gas type and which gas pressure
2.
your local gas supply network uses before installing
the appliance, and ensure that the gas setting for
the appliance complies with this information. If the
appliance settings have to be changed, follow the
instructions in the section "Gas connection and con-
version to a different gas type".
This appliance is not connected to a waste gas
3.
main. It must be positioned and connected in ac-
cordance with the applicable installation conditions.
Do not connect the appliance to a waste gas main.
Ensure that suitable ventilation measures are carried
out.
Establish the gas supply using a permanent, non-
4.
elastic connection, such as a gas pipe or a safety
hose.
If you use a safety hose, ensure that the hose is not
5.
trapped or compressed. The hose must not come
into contact with hot surfaces.
The connection must have an easily accessible
6.
locking device.
Flexible hoses
Do not pinch or squeeze hoses.
1.
Do not subject the hoses to twisting or pulling
2.
forces.
Keep the hoses away from sharp edges.
3.
Do not let the hoses come into contact with parts
4.
that may reach a temperature higher than 70 °C
above room temperature.
5.
Ensure that the full length of the hoses can be ac-
cessed for testing.
Checking for leaks
After connecting the gas pipe, use soapy water to
check the connections for leaks.
Starting up
Start up the appliance in accordance with the in-
1.
struction manual.
Ignite all of the burners.
2.
Check the stability of the flames at a high and
low setting.
Moving or transporting the appliance by the gas
pipe (collector) or by the door handle
Do not move the appliance by pulling on the gas
1.
pipe (collector).
a The gas pipe may be damaged and a gas leak may
occur.
Do not move the appliance by holding it by the door
2.
handle.
a This may damage the door hinges and door handle.
4.3 Electrical connection
The appliance must only be connected to the mains
electricity supply by a licensed specialist. You must
comply with the requirements of your electricity sup-
plier.
¡ The appliance is designed for operation at 220-240
V. A 16 A fuse is required for the connection.
¡ Any damage arising from the appliance being con-
nected incorrectly will invalidate the warranty.
CAUTION ‒ !
The power cable may be damaged. The damage to the
power cable may lead to a dangerous situation.
The power cable must be replaced by the manufac-
turer, their after-sales service or a similarly qualified
person.
¡ The appliance must always be disconnected from
the power supply when installation work is being
carried out.
¡ The appliance fulfils the requirements of protection
class I and must only be connected to an earthed
mains socket.
¡ The mains power cable must be at least type H05 V
V-F 3G 1.5 mm².
Installation and connection en
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgx5g7w50 series6 series

Table of Contents