3.4 Gas selection
WARNING!
Information for authorised installer only.
1. Deactivate the hob.
2. Press and hold
3. Within 7 seconds, press and hold the
space below the three illuminated LEDs
next to the
for 3 seconds.
4. Press the
symbol of the middle burner
until G1 appears on the display.
0
G20 20 mbar
3.5 Adjustment of minimum level
WARNING!
Information for authorised installer only.
Switch off the hob before the adjustment.
To adjust the minimum level of the burners:
1. Deactivate the hob.
2. Press and hold
3. Within 7 seconds, press and hold the
space below the three illuminated LEDs
next to the
symbol for 3 seconds.
4. Press
symbol of the middle burner 3
times.
The display shows G2 mode.
5. To enter the mode press
middle burner.
6. Wait 5 seconds after selecting the mode.
The burner ignite at minimum level and the
control bar shows
7. To increase or decrease the value and
adjust the minimum level press
symbols of the middle burner.
8. Wait 5 seconds to send the selected
value to power board.
for 3 seconds.
Liquid gas 29 mbar
for 3 seconds.
symbol of the
.
or
5. To enter the gas selection mode press
symbol of the middle burner.
Timer display shows selected gas type.
6. Press
table below.
7. To confirm the gas type press
of the middle burner.
Press
to exit the mode or wait for
Automatic Switch Off function activates.
Gas selection
1
9. Check if the minimum level is correct and
press
level.
If the minimum level is incorrect, repeat
the steps 6 and 7.
10. Press
select the next burner and repeat the
steps 5-8.
The procedure starts from the middle burner
and goes through the left burner, the right
front burner to the right rear burner.
To exit the mode press
WARNING!
Make sure the flame does not go out
when you move quickly from the
maximum to the minimum heat setting
position.
WARNING!
Do not set the G3 and G4 modes. It is for
Authorised Service Centre only.
3.6 Electrical connection
• Make sure that the rated voltage and type
of power on the rating plate agree with the
to set the gas type according to
2
Safety risk, do not use 2 gas selec‐
tion. Use only 0 or 1 gas selections
depend on gas supply.
symbol to confirm the minimum
symbol of the middle burner to
.
ENGLISH