2-Wire Audio System Installation Manual Page | 1...
Page 2
System Layout: Introduction The Atigo door entry system is a simple 2- Maximum of 4 handsets can be connected to wire solution that can be expanded up to 4 a single call button. entrance panels and 32 handsets. Maximum of 32 handsets can be connected in Programming of the audio module is done via Daisy-Chain or Star configuration.
Page 3
DIP switch settings for A3200 Audio module A3200 The audio module is configured by 6 DIP switches. The DIP switches can be modified either before or after installation. Restarting the Audio module is necessary whenever the DIP switches have been modified.
Page 4
Audio module functions Sound theme settings. programming When the Audio Module is in programming mode: Press and hold Key A for 3 seconds to enter the Sound Theme Mode. The Status indicator will turn on and current theme sound, will play. Press Key A again to play the next theme.
Page 5
Electric lock mode settings Electric lock with additional power supply. Set the Audio Module in to Programming mode: Contact rating is limited to 24V DC and MAXIMUM CURRENT of 1000mA. Press Key A, the Unlock Indicator will The jumper JP-LK must be taken off turn on with the warning sound of a long before connecting.
Page 6
Triggering a Gate automation: Electric lock powered by internal 12V DC output. When triggering a gate, must use A2601 auxiliary relay. NOTE: Do not connect Gate contacts to Internal output is limited to 12V DC and Video module as this will cause permanent MAXIMUM CURRENT of 200 mA.
Page 7
Single module connections Terminals Connecting multiple modules 1. INPUT (Max. 4) Connect to CN/KMB port on audio module 2. OUTPUT Connect to next call module. 3. J3 Call buttons 1, 3, 5, 7 4. J4 Call buttons 2, 4, 6, 8 P a g e...