Page 2
Introduction Maximum of 4 monitors can be addressed to a single call button. The Atigo door entry system is a 2-Wire system that can be expanded up to 4 Maximum of 4 monitors can be connected in entrance panels and up to 32 non-Wi-Fi daisy chain configuration internal monitors per system.
Page 3
DIP switch settings for A3101 Video camera module A3101 The video module is configured by 6 DIP switches. The DIP switches can be modified either before or after installation. Restarting the camera module is necessary whenever the DIP switches have been modified.
Page 4
Video module functions and Sound theme settings. programming In Standby, activate programming mode by setting DIP switch 6 to ON position. Press and hold “Touch Key A” for 3 seconds. The hourglass indicator will turn on and current theme will play. pressing “Touch key A”...
Page 5
Electric lock mode settings Electric lock with additional power supply. In Standby, activate programming mode by setting DIP switch 6 to ON position. Fail Safe Contact rating is limited to 24V DC and MAXIMUM CURRENT of 1000mA. Press “Touch key A”, the Door Open The jumper JP-LK must be taken off Indicator will turn on with a long Beep before connecting.
Page 6
Triggering a Gate automation: Electric lock powered by internal 12V DC output. When triggering a gate, must use A2601 auxiliary relay. NOTE: Do not connect Gate contacts to Internal output is limited to 12V DC and Video module as this will cause permanent MAXIMUM CURRENT of 200 mA.
Page 7
Single module connections Connecting multiple modules (Max. 4) Terminals 1. INPUT Connect to CN/KMB port video module 2. OUTPUT Connect to next call module. 3. J3 Call buttons 1, 3, 5, 7 4. J4 Call buttons 2, 4, 6, 8 P a g e...