(MOBILE HOMES OR AS CODE MY REQUIRE)
1. The copper ground strap connected between the
neutral (middle) post of the main terminal block and the
chassis MUST be removed and discarded. Keep the
green ground screw. Only a 4 conductor cord should be
used.
2. The green wire from the service cord must connect to
the range chassis using the green ground screw.
3. The white wire of the service Cord must connect to the
neutral (middle) post of the main terminal block. The
other two wires of the service cord connect to the red
and black posts of the main terminal block,
respectively.
4. Position the strain relief with flanges on top of conduit
plate as shown and secure to service cord.
RED--_
VtI-I I TE_\
BLACK---__
GROUNO
STRAP
=..-TT._I:_,#) j_
(CHASSIS
GROUND) __
FtOOR
MAIN
TERMINAL
CONNECTION
BLOCK
/MIDDLE
WiRE
OF
SERVICF
CORD
,-- CONDUIT
PLATE
[
OONDUII
PLATE
I
1
I
I
REMOVE
KNOCKOU_FOR_O_
SERVICE
CORD
(PIOTAIL)
USE.
OUTLEt
MOUNTED
FLUSH
TO WALL
ALTERNATE INSTALLAT10N
OUTLET
TO BE
ROTATED
A_
SHOWN
IF NOT
FLUSH
TO WALL
FIGURE 10
4 WIRE PLUG
(MOBILE HOMES OR AS CODE MY REQUIRE)
1. The range conduit must be routed and properly
connected to an approved electrical junction box
behind the range.
2. The red and black wires from the range conduit must
respectively connect to the red and black service wires.
An approved wire connector must be used.
3. The white wire from the conduit must be connected to
the white service wire.
4. The uninsulated (bare) wire from the conduit must be
connected either to a green or bare service wire.
!iii!i!i!i
iiii!il i !iiii iiiiiiii!iiiiii!
Slide-in Models Only With 3-Wire Service Cord
Attached.
Disconnect range from power. Remove the access cover
on back of range and remove the 3-wire service cord from
the main terminat block. Follow instructions as outlined in
figure 10 to connect the 4-wire service cord.
NOTE: Cord replacement-
ONLY a power supply cord
rated at 240 volts minimum, 40 amperes or 50 amperes
power supply cord that is marked for use with nominal 1
3/8" (34.93 mm) diameter connection opening, with closed
loop terminals and marked for use with ranges shall be
used.
NOTE: ROUTE
RANGE
CONDUIT
SO
THAT
IT
CONTAINS NO KINKS AND DOES NOT INTERFERE
WITH INSTALLATION OF UNIT.
WHITE_
APPROVED
CONNECTORS
CONDUIT
CONNECTOR
BOX
L1
NEUTRAL
GROUND
CIRCUIT
(POWER SUPPLY)
WIRING METHODIF CODE DOES NOT PERMIT GROUNDING
THROUGH NEUTRAL CONDUCTOR& ALSO REQUIRED IN
MOBILEHOMES.
FIGURE 11
4 WIRE CONDUIT