Mode Switch - Miller Invision 456P Owner's Manual

Hide thumbs Also See for Invision 456P:
Table of Contents

Advertisement

3-3.
Meter Functions For Invision 456P
1
Power
Switch
~
The
fan
motor
is
thermostatically
control/ed and
only
runs
when
coo/mg
is
needed.
2
Voltmeter
(see
Section
3-5)
3
Ammeter
(see
Section
3-5)
4
V/A
(Voltage/Amperage) Adjust
Control
5
Voltage/Amperage
Control Switch
For front
panel
control,
place
switch in Panel
position
and
use
the
V/A
Adjust
control.
For remote
control,
make connections to Re
mote 14
receptacle,
and
place
switch in Re
mote
position.
In most
modes,
remote
control
is
a
percent
of the
V/A
Adjust
control
setting.
Value selected
on
V/A
Adjust
is maximum
available
on
remote. In the
MIG
mode,
remote
control
provides
full
range
of unit
output
re
gardless
of
V/A
Adjust
control
setting.
6
Mode Switch
The Mode switch
setting
determines both the
process arid
output On/Off
control
(see
Sec
tion
3-6).
Source of control
(panel
or
remote)
for the
amount
of
output
is selected
on
the
V/A
Control switch.
For Air Carbon Arc
(CAC-A) cutting
and
goug
ing,
place
switch in the Stick
position.
For best
results, place
Inductance/Dig
control in the
maximum
position.
7
Inductance/Dig
Control
Control
adjusts Dig
when the Stick
or
CC
mode is selected
on
the Mode switch. When
set towards
minimum,
short-circuit
amperage
at low
arc
voltage
is the
same
as
normal weld
ing
amperage.
When set towards
maximum,
short-circuit
am
perage is increased
at low
arc
voltage
to
assist
with
arc
starts
as
well
as
reduce
sticking
while
welding (see volt-ampere
curves
in Section
2-3).
Select
setting
best suited
for
application.
Control
adjusts
inductance when MIG
position
is selected
on
the Mode switch. Inductance
determines the wetness
of the weld
puddle.
When
set
towards
maximum,
wetness
(puddle fluidity)
increases.
When Pulsed
MIG,
or one
of the TIG modes is
selected,
this control is not functional.
N OT E
The
meters
display
the actual weld
output
values for
approximately
three seconds
after the
arc
is broken.
Mode
Meter
Reading
At idie
Meter
Reading
While
Welding
MIG
I
24.5
A
Preset Volts
Blank
24.5
250
I
Actual Volts
Actual
Amps
Pi~sed
IPPPI
Pulse
Display
Pulse
Display
24.51
12501
Actual Volts
Actual
Amps
3-4.
Front Panel Controls For Phoenix 456
CC/CV
I
ON
-e
0
___
A
POWER
V/A
ADJUST
MADE IN
1NDUCTANC\\DIG
7
PANEL
z
REMO\
5
ST-179 542-B
OM-186 989
Page
16