6-2. Mode Switch Settings

Switch Position
(1) An ArcReach device will override any remote control connected to remote 14 receptacle.
*See Section 6-5 For Alternate Configuration Functions.

6-3. Associating ArcReach Device To ArcReach Power Source

Quick Setup Guide:
1
Make connections between power source and ArcReach device. (See section pertaining to mode being used for typical connection
diagrams).
2
This power source has the ability to associate with an ArcReach device at power up, or when an ArcReach wire feeder is triggered. The
Mode Switch on this power source must be set to an "OUTPUT ON" mode to associate with another ArcReach device.
3
See instructions in the owner's manual for the specific ArcReach device to associate the device to this power source.
4
During the association process the Remote In Use indicator will blink.
5
When the association process is complete, the Remote In Use indicator will be lit. Dependent on the capabilities of the ArcReach device; the
mode switch, voltage/amperage adjustment, and Arc Control adjustment may be overridden by the ArcReach device.
6
The association ends approximately 10 seconds after the ArcReach device is disconnected or turned off and the power source is not welding.
After association has ended the Remote in Use indicator will turn off and control will revert back to panel operation.
6-4.

Optional Low Open Circuit Voltage (OCV) Welding Modes

Low OCV Operation
The unit can be optionally configured for low open circuit voltage (OCV) operation in SMAW (Stick) and CAC-A (Gouge) Output-On modes. When
the unit is configured for low OCV operation, a low sensing voltage (approximately 12 VDC) is present between the electrode and the workpiece
prior to the electrode touching the workpiece. Consult a Factory Authorized Agent for information regarding how to configure unit for low OCV
welding operation.
.
A complete Parts List is available at www.MillerWelds.com
Process
Output Control
GMAW/FCAW Gas (1)
FCAW−S No-Gas (1)
SMAW Stick (1)
CAC−A Gouge (1)
GTAW Lift-Arc TIG (1)
GTAW TIG
SMAW Stick
SAW Subarc
GMAW/FCAW Gas
Panel Adjust
Output On
Volts
Output On
Volts
Output On
Amps
Output On
Amps
Output On
Amps
Remote 14
Amps
Remote 14
Amps
Remote 14
Volts
Remote 14
Volts
Remote Adjust
Volts
Volts
No Remote Adjust -
Panel Only*
No Remote Adjust -
Panel Only*
% Panel Amps
% Panel Amps
% Panel Amps
Volts
Volts
OM-287308 Page 23