Bosch HGVDF0V51S User Manual And Installation Instructions page 10

Free standing cooker
Table of Contents

Advertisement

en Installation and connection
¡ Do not use any multiple plugs or multi-connectors
and extension cords.
¡ The earthing system is correctly installed.
4.4 Appliance categories
Country
RU, BY, KZ, AM, KG
UA
MA
AE, LB, JO
EG
4.5 Setting up the appliance
Place the appliance on a smooth surface.
Never set up the appliance behind a decorative door or
the door of a kitchen unit. There is a risk of overheat-
ing.
¡ Install the appliance in accordance with the spe-
cified dimensions.
¡ The distance between the top edge of the cooker
and the bottom edge of the extractor hood must
meet the requirements of the extractor hood manu-
facturer.
¡ Ensure that the appliance is not moved again after it
is set up.
¡ In particular, the distance from the high-output
burner or wok burner to the fronts of adjacent units
or from the wall must be at least 50 mm.
Positioning and levelling
Positioning the appliance
When installing the appliance, ensure that the final loc-
ation has sufficient space that the appliance can be
pulled out for cleaning and maintenance work.
The ground must be hard and stable. The wall directly
behind the appliance must be made of non-flammable
material, such as tiles.
If you have to pull the appliance while positioning it, en-
sure that the adjustable feet are screwed in tightly.
Aligning the appliance
Aligning the appliance
Turn the adjustable feet to align the appliance
10
¡ If using a residual current device, only use one that
¡ The mains cable does not come into contact with
Category
II 2H3B/P
II 2H3B/P
I 3+
II 2H3B/P
II 2H3+
Note:
¡ Do not align the appliance until all other work has
¡ You can use the adjustable feet to increase the
¡ You must check the alignment of the appliance
Adjacent units
Any adjacent units must not be made of flammable ma-
terials.
¡ The fronts of any adjacent units must be heat-resist-
¡ If the appliance is installed very close to other units,
Note: Ensure that the clearance between the appliance
and the back wall is at least 10 mm.
bears the mark
. The presence of this mark is the
only way to be sure that it fulfils all the applicable
regulations.
heat sources.
P (mbar)
2000 тта–3000 тта
20 - 28 - 30
28 - 30/37
20 - 28 - 30
20 - 28 - 30/37
been completed.
height of the appliance by up to 45 mm.
once it has been installed in the intended location.
ant up to at least 90 °C.
the minimum clearances specified in the figure must
be complied with.

Advertisement

Table of Contents
loading