Additional information
Additional information on how to commission an NX component is provided in:
• Commissioning Manual IBN CNC: NCK, PLC, Drive
See also
Connecting digital inputs/outputs (Page 88)
12.1.5
Technical Data
Table 12-9
Protection class
Degree of protection to EN 60529
Approvals
Pollution degree
Cooling
Mounting position
PE/ground connection
Table 12-10
Input voltage
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current
Power loss
Dimensions WxHxD (with spacers)
Weight
12.2
PP 72/48D PN and PP 72/48D 2/2A PN
12.2.1
Description
Characteristics
The PP 72/48D PN and PP 72/48D 2/2A PN I/O modules are simple modules (without a separate
housing) for connecting digital and analog input/outputs as part of an automation system based
on PROFINET IO.
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH
Safety-related data
Electrical and mechanical data
Connectable components
12.2 PP 72/48D PN and PP 72/48D 2/2A PN
III
IPXXB
CE, cULus
2
Open-circuit ventilation
Vertical
at the housing with M5 screw Torx / 3 Nm
24 V DC (20.4 – 28.8)
3.35 A
15 W
25 x 414 x 272 mm
2.58 kg
111