7.3

Configuration mode (Mode 2)

Type
When M 0 = ON and M 1 = OFF, the module works in mode 2
send
Wireless launch closed
receive
Wireless receive closed
configure
The user can access the register to configure the module operating state
7.4

Depth sleep mode (mode 3)

Type
When M 0 = OFF and M 1 = OFF, the module works in mode 3
send
Unable to transmit the wireless data.
receive
Unable to receive the wireless data.
When entering from the hibernation mode to the other mode, the module will reconfigure the parameters, and the
pay attention to
AUX remains low during the configuration process;
After the output high level, it is recommended that the user detect the T _ BUSY rising edge.

8. Register read/write and control

8.1

Command format

Under the configuration mode (mode 2: M 1 = OFF, M 0 = ON), the supported instruction list is as follows (when
setting, only 9600,8N1 format is supported):
Instruction
No
format
1
Set the register
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
Instructions: C0 + starting address + length + parameter
Response: C1 + starting address + length + parameter
Example 1: The configuration channel is 0x09
Command start address length parameter
Send to: C0 05 01 09
Return: C1 05 01 09
Example 2: simultaneously configure the module address (0x1234), network address
(0x00), serial port (9600 8N1), empty speed (2.4K)
Send to: C0 00 04 12 34 00 60
Return: C1 00 04 12 34 00 60