network ID:0~255
Key: 0~65535
When the user uses the upper computer configuration relay mode, they need to pay special attention to, because in
the upper computer, each parameter is decimal display mode, so the module address and network ID need to be
filled in through the conversion input system;
If the network ID input by the transmitter A is 02 and the network ID input by the receiver B is 10, then the relay R
sets the module address, convert the hex value 0X020A into the decimal value 522 as the module address filled in
by the relay R;
That is, the module address value of the relay terminal R that needs to be filled in is 522.

12. Configure device

12.1. Connection diagram

Mode
Configuration
mode
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
M1
M0
OFF
ON
Description
Stations can only be programmed by using the configuration
software in the current mode
E90-DTU(900SL33) User Manual