Frequency Range And Channel Number; Transmit Power Level; Air Rate Grade; Current Parameters - Ebyte E90-DTU User Manual

Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
5.3

Frequency range and channel number

Model
E90-DTU(900SL33)
★ Note: In the same area, multiple sets of transmission stations are used to communicate one to one at the same time. It
is suggested that the channel interval be set above 2 MHz.
5.4

Transmit power level

Model
E90-DTU(900SL33)
★ Note: The lower the transmission power is, the closer the transmission distance is, but the working current will not
decrease in the same proportion, so it is recommended to use the maximum transmission power.
5.5

Air rate grade

Model
E90-DTU(900SL33)
Note: The higher the air speed setting, the faster the transmission rate, and the closer the transmission distance; so if
the rate meets the usage requirements, the lower the air speed, the better.

5.6 Current parameters

Model
E90-DTU(900SL33)
Note: It is recommended to retain more than 50% of the current margin when selecting the power supply, which is
conducive to the long-term and stable operation of the radio station.
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
Default
Band Range
Frequency
Hz
850.125~
868.125MHz
930.125MHz
2W
Factory default
Default
Equal series
bps
2.4k
6
Emission current mA
12V
650
Channel
Spacing
Hz
Hz
1M
1W
500m W
Air rate grade
2.4、4.8、9.6、19.2、38.4、62.5k
Waiting current mA
24V
12V
330
10
E90-DTU(900SL33) User Manual
Description
81, Half duplex
250m W
bps
24V
6
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

900sl33

Table of Contents