To exit the Heating curves setting [OTC] menu, press the button
If the room temperature is lower than the desired value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
90
85
80
70
60
50
40
30
20
20
fig. 22- Compensation curves
Adjustments from Remote Timer Control
If the boiler is connected to the Remote Timer Control (optional), the previously described adjustments are
A
managed as described in table 2.
Table 2
Heating temperature adjustment
DHW temperature adjustment
Summer/Winter Switchover
Eco/Comfort selection
Sliding Temperature
EN
10
9
8
7
10
0
-10
Adjustment can be made from the Remote Timer Control menu and the boiler control
panel.
Adjustment can be made from the Remote Timer Control menu and the boiler control
panel.
Summer mode has priority over a possible Remote Timer Control heating request.
Disabling DHW from the Remote Timer Control menu forces Economy mode. In this
condition, with the off button (detail 7 - fig. 1) on the boiler panel, it cannot be switched
to Comfort mode.
By enabling DHW from the Remote Timer Control menu, the boiler selects Comfort
mode. In this condition, with the off button (detail 7 - fig. 1) on the boiler panel, one of
the two modes (Economy - Comfort) can be selected.
Both the Remote Timer Control and the boiler card manage the Sliding Temperature
adjustment: between the two, the Sliding Temperature of the boiler card has priority.
cod. 3542B970 - Rev. 02 - 09/2023
repeatedly until reaching the main screen.
OFFSET = 20
6
90
85
5
80
70
4
60
50
3
40
30
2
20
1
OFFSET = 40
90
85
80
70
60
-20
50
40
30
20
fig. 23- Example of compensation parallel
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
curve offset