Ferroli DIVATOP D Instructions For Use, Installation & Maintenance page 71

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 45
Index
Description
b09
DHW demand type selection
Flowmeter timing (b02=1)
Flowmeter timing (b02=2)
b10
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
DHW mode activation flow rate (b02=1)
DHW mode activation flow rate (b02=2)
b11
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
b12
Enable Auto-Settings procedure
Index
Description
P01
Ignition ramp Offset
P02
Heating ramp
P03
Heating standby time
P04
Heating Post-Circulation
P05
Heating user max. setpoint
P06
Max. output in heating
Burner shutdown in DHW (b02=1)
P07
Burner shutdown in DHW (b02=2)
Hot water tank hysteresis (b02=3)
Hot water tank hysteresis (b02=4)
DHW standby time (b02=1)
DHW standby time (b02=2)
P08
DHW standby time (b02=3)
DHW standby time (b02=4)
DHW user max. setpoint (b02=1)
DHW user max. setpoint (b02=2)
P09
DHW user max. setpoint (b02=3)
DHW user max. setpoint (b02=4)
Anti-inertia function temperature (b02=1)
No effect on adjustment (b02=2)
P10
Flow temperature in DHW (b02=3)
Flow temperature in DHW (b02=4)
71
Range
0 = Flow switch
1 = Flowmeter (190 imp/l)
2 = Flowmeter (450 imp/l)
3 = Flowmeter (700 imp/l)
0 = Deactivated
1 ÷ 10=seconds
0=Deactivated
1-10=seconds
--
--
10 ÷ 100 L/min/10
10 ÷ 100 L/min/10
--
--
0 = Disabled
1 = Enabled
Range
0 - 40
1-20°C/minute
0-10 minutes
0-20 minutes
31-85°C
0-100%
0=Fixed
1=Linked to setpoint
2=Solar
3 = DO NOT USE
4 = DO NOT USE
0=Fixed
1=Linked to setpoint
2=Solar
3 = DO NOT USE
4 = DO NOT USE
0 (do not use) 1-2-3-4°C
0 (do not use) 1-2-3-4°C
0-60 seconds
0-60 seconds
0-60 seconds
0-60 seconds
50-65°C
50-65°C
50-65°C
50-65°C
5-85°C
--
70-85°C
70-85°C
cod. 3542B970 - Rev. 02 - 09/2023
DIVATOP D F
Default
2
0
15
0
Default
20
5
2
6
80
100
0
30
50
0
EN