Ferroli DIVATOP D C Instructions For Use, Installation & Maintenance page 47

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 37
DIVATOP D C
Display adjustment menu [Display]
In this menu it is possible to set some display parame-
ters.
[Contrast] - Contrast adjustment
[Brightness] - Brightness adjustment
[Backlight time] - Display lighting duration
[Lock time]* - Button lock
After button pad inactivity for a time equal to
the set value (minutes), the symbol
appears and the buttons are inhibited.
To reactivate the button pad, simultaneously
press the buttons
bol
disappears (about 2 sec.).
[Reset] - Restore factory values
Sliding Temperature
When the external probe (optional) is installed, the boiler adjustment system works with "Sliding Temperature". In this
mode, the heating system temperature is regulated according to weather conditions, to ensure high comfort and energy
efficiency throughout the year. In particular, as the outside temperature increases the system flow temperature decrea-
ses according to a specific "compensation curve".
With "Sliding Temperature", the temperature set using the heating buttons (details 3 and 4 - fig. 1) becomes the maxi-
mum system flow temperature. It is advisable to set a maximum value to allow system adjustment throughout its useful
operating range.
The boiler must be adjusted at the time of installation by qualified personnel. However, the user can make any further
adjustments necessary to optimize comfort levels.
Compensation curve and curve offset
From the main screen, press the button
heating select the installer menu [SERVICE] and confirm with the button
menu [SERVICE]' on page 45 ***) and press the button
Heating curves setting [OTC] and confirm by pressing the button
Curve: select this item and use the buttons
DHW to set the desired curve from 1 to
10.
By setting the curve to 0, the sliding tempe-
rature adjustment is disabled (see fig. 22).
Offset: Access this sub-menu to access parallel off-
set of the curves using the buttons
DHW. Refer to fig. 23 for the characteris-
tics.
EN
and
until the sym-
to access the navigation menu [MENU]. Using the buttons
and
and
cod. 3540000140 - Rev. 02 - 09/2023
DISPLAY
Contrast
Brightness
Backlight time
Lock time
Reset
fig. 20
. Enter the password (see *** 'Installer
. Using the buttons
and
.
OTC
Curve
Offset
fig. 21
5
Max
10m
OFF
and
heating select the menu
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Divatop d c24Divatop d c320dtc4yya0dtc7yya

Table of Contents