Page 1
User's Manual InBody970 User's Manual for Measurement Guide and Setup Thank you for purchasing the InBody970. This user's manual describes all the features of the InBody970. Please read before use and keep it in a safe place. By following properly these instructions, you will be able to use the InBody970 more safely and effectively.
Page 2
Percent body fat could be a useful parameter than just weight to verify health condition in children and adolescents. • Sarcopenia: InBody Test is a quick and easy way to provide the Skeletal Muscle mass Index (SMI), which is the sum of the skeletal muscle mass of the limbs divided by the height square.
Page 3
Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd. under the copyright laws. This manual may be printed incorrectly and subject to change without notice. InBody Co., Ltd. shall not be liable for any errors, incidental, or consequential damages that occurred by not complying with the content of the User᾽s Manual.
III. Transportation and Storage A. Cautions during Transportation B. Repacking Instructions C. Transportation and Storage Environment IV. Frequently Asked Questions (FAQ) A. Regarding the Device B. Regarding the InBody Test V. Others A. Exterior and Functions B. Safety Information C. Classifications D. Specifications E.
I. InBody Installation A. Product Components InBody970 consists of the following components. Make sure all of the following components are present. * Please check if the InBody970 has any damage prior to installation. InBody970 ❶ Power Adapter ❷ Input Button Power Cable ❸...
B. Installation Environment Check the environment before installing the InBody970. This device is suitable for indoor use. If installing this device outdoors, the following requirements must be fulfilled. Temperature 10 ~ 40°C (50 ~ 104°F) Relative humidity 30 ~ 75% RH Atmospheric pressure 70 ~ 106kPa C.
Page 8
• Do not clean the foot electrode and the hand electrode with detergent. If liquid cleaner flows into InBody970, it may cause corrosion and malfunction. For cleaning the InBody970, use an InBody Tissue (wet tissue). 2. Raise the InBody970 upper section to the end and then remove the protective packaging vinyl.
Page 9
3-terminal outlet with a ground terminal. ❸ * The InBody970 can be connected to optional devices such as stadiometer, blood pressure monitor, and Yscope and PC program, LookinBody120. Please refer to "E.Connecting Compatible Device" in "I.InBody Installation" in this User's Manual. ❶ Power Inlet ❸...
Page 10
This can minimize the electric shock to the InBody970. • Use the adapter provided by InBody. The InBody970 may malfunction when using other adapters. • If you are operating the device in a place where the altitude is 2,000m or higher, the weight measurement may be affected.
3. Enter the administrator password to set the password. This screen will appear only once for initial password setup. * Be careful not to forget the password you set. If you have forgotten your password, please contact InBody Customer Service.
Page 12
: This option allows checking, printing or deleting the test result stored in the InBody970 as a membership number or mobile number. 07. Export Data as Excel : This option allows copying the test result saved in the InBody970 to InBody USB as an Excel file format. 08. Data Backup/Restore/Combine : This option allows saving the test results to InBody USB for backup or restores the test results backed up to the InBody970.
Page 13
BSM Stadiometer series, BPBIO Blood Pressure Monitor series, or Yscope. * For details to connect Bluetooth, please refer to "E Connecting Compatible Device" in "1. InBody Installation" in this User's Manual. 18. Manual/Automatic Weight : Select whether to proceed testing by entering the subject's weight manually or by taking the weight measurement automatically.
Page 14
2) FAQ: See additional information on how to use the InBody. Refer to FAQ checklist when there are problems that occur while using the the InBody. 01. Customer Service Information : This shows the information saved in the "Setup: 24. Customer Service Information". so that you can use it when you have an inquiry about InBody or a problem occurs.
Administrator Menu. 2) Stadiometer The height values measured by the stadiometer are sent to InBody970 when it is connected to InBody970. * Please make sure to connect only BSM Stadiometer series provided by InBody. Turn off InBody970. ❶ * When InBody970 is already turned on, the stadiometer might not properly connect.
Page 16
* If you select the type of Result Sheet at "13.Outputs/Interpretations for Result Sheet" in Setup in Administrator Menu and then select blood pressure in the sub options, then you can print the blood pressure value on the InBody Result Sheet.
Page 17
• Avoid laying cables connecting to compatible devices where people frequently pass. This may cause individuals to trip over or become injured. • Do not connect compatible devices that are not specified from InBody to the InBody970. Otherwise, it may cause malfunction.
Page 18
* While InBody970 and LookinBody120 are already connected via Bluetooth, and if you are trying to connect other compatible devices via Bluetooth, the original connect between InBody970 and LookinBody120 will stop. 5) Turn on one of the InBody recommended compatible device and check the product name and serial number on the name plate attached to the compatible device.
Page 19
8) If the compatible device is paired properly, the Bluetooth ID of the device connected to the InBody970 will appear as shown below. 9) Press [Exit] to return to the test standby screen, and the Bluetooth icon and the corresponding device icon will be displayed on the upper left corner screen.
Page 20
Once InBody970 is connected to the Internet, you can use it to connect the Cloud Services or LookinBody Web * If the Cloud Service does not work or if LookinBody Web is not recognized, please contact InBody Customer Service. 1) Connecting LAN Press the [Administrator Menu] on the test standby screen.
Page 21
2) Connecting Wi-Fi Press the [Administrator Menu] on the test standby screen. ❶ Enter the password to enter the Administrator Menu. ❷ Go to "16. Internet Options" in Setup. ❸ Press Wi-Fi and press [Next] ❹ * Depending on the service area, you may need to enter the IP address or DNS address manually. Select the Wi-Fi to be connected.
F. Precautions for Maintenance Caution Do not place any objects on the footplate. • Do not let children jump on the footplate as they might fall and get injured. • Do not apply excessive force on the device. • Be careful not to get your fingers caught in the shoulder joint when moving the handle. •...
If your palms and soles of feet are dry or if you have a lot of dead skin cells, the test may not work well due to poor • electrical contact between the electrode and the body. Wipe your palms and soles of feet with an InBody Tissue (wet tissue) before measuring.
B. Test Instructions 1. Step up onto the footplate with bare feet. * The screen changes during the test depending on the setting in "02. Self-Mode or Professional Mode" in the Administrator Menu. Professional Mode:The screen is configured for testing with an instructor. (Measurement information is managed by user ID.) Self Mode: The screen is configured for testing alone.
Page 25
5. When pressing [Exit] or if InBody BAND is not recognized, the InBody970 checks your fingerprint. 6. If your fingerprint is recognized, the personal information will be automatically displayed on the screen as shown below. *If fingerprint is placed differently from when it was initially registered, personal information may not load properly.
Page 26
9. Maintain proper posture to take the test. * For proper test posture, refer to "C.Test Posture". * When the hand and foot electrode is recognized, the InBody Test begins automatically. 10. InBody Test begins. *It will take 90 seconds to complete the test.
C. Test Posture The subject must maintain proper posture to have accurate test results. Your arms must not touch the sides of your body. Keep the arms straight. The thighs should not touch each other. Hold the hand electrode so that the 4 fingers wrap the surface of the bottom hand electrode, and place the thumb on the oval...
III. Transportation and Storage A. Cautions during Transportation To transport the InBody970 safely, two people should keep the device in a horizontal position. B. Repacking Instructions Once the InBody970 is installed, avoid transporting the device. If it must be transported, repack it in the following sequence.
After sealing it, transport only by holding the handle. Caution • When repacking the device, the protective packaging materials provided by InBody must be used. C. Transportation and Storage Environment InBody970 should be transported or stored under the following conditions.
Insert the power cord completely into the adapter. The problem may occur if you are using the power adapter that is not provided • by InBody. Always connect a power adapter (DC 12V, 3.4A/3.34A) provided by InBody. Power Adapter...
Page 31
• recognized. If there are too many Bluetooth devices around, the connection may delay. • If InBody BAND is not properly connected, turn off or deactivate unused • Bluetooth devices to improve the recognition rate. Fingerprint recognition Fingerprint recognition may not work well if the subjects' finger prints are •...
It's good to check up often, but it's also important to keep track of your • body's changes over time through steady tests. Body composition changes can be seen on the InBody result screen and the • InBody Result Sheet.
Fingerprint Recognition Sensor: The sensor recognizes the left thumb fingerprint and saves or loads the personal ❷ information automatically. InBody BAND Recognition Sensor: Receives personal information in wireless connection with InBody BAND. ❸ Body: Connects the upper section and the lower section.
Page 34
2. Footplate Front Sole Electrode Area: This area is the electric contacting area where user's front foot treads to contact during ❶ the test. Rear Sole Electrode Area: This area is the electric contacting area where user's heel treads to contact during the ❷...
Page 35
3. Rear view Rear Cover: Used for inspecting internal inspections, etc. Verified InBody service engineer can only open it. ❶ LAN Port (10/100T-Base): Connect the InBody970 to the Internet or LookinBody120 installed on the PC ❷ via wire connection. * You can connect the InBody970 to LookinBody120 installed on the PC if at least one of ❷, ❹, ports is connected.
Product Name: Impedance Body Fat Analyzer Model name: InBody970 Company name: InBody Co., Ltd. Manufacturer / Country of manufacturer: InBody Co., Ltd. / Korea Date of Manufacture: Rear side Caution • This device is a Class IIa electromagnetic wave compatible device and can be used in all areas.
Basal Metabolic Rate, Waist-Hip Ratio, Visceral Fat Level, Visceral Fat Area, Obesity Degree, Bone Mineral Content, Body Cell Mass, Arm Circumference, Arm Muscle Circumference, FMI, FFMI, SMI, Recommended Calorie Intake, Calorie Expenditure of Exercise, InBody Score) • Blood Pressure (Max/Min/Pulse Rate, Avg/Pulse pressure/R.P.P) •...
Page 38
Body Composition Result parameters and Result interpretation Result Sheet for Children • Body Composition Analysis (Total Body Water, Protein, Mineral, Body Fat Mass, Fat Free Mass, Soft Lean Mass, Weight) • Muscle-Fat Analysis (Weight, Skeletal Muscle Mass, Body Fat Mass) •...
Comparison • Body Composition Summary (Fat Free Mass, Body Fat Mass, Intracellular Water, Extracellular Water, Body Result Sheet Water, ECW Ratio, Weight) • Body Composition Analysis (Lean Mass, ICW, ECW, Fat Mass, ECW/TBW): Whole Body, Right Arm, Left Arm, Trunk, Right Leg, Left Leg •...
Fingerprint Recognition Recognizes the fingerprint of the measurer and automatically inputs personal information to the InBody970 Function Backup data Backup data saved in InBody970 by using an InBody USB QR Code See your result on InBody mobile App F. Other Specifications...
Page 44
1639 ⓒ2022 InBody Co., Ltd. All rights reserved. IM-ENG-I4-D-220426...
Need help?
Do you have a question about the 970 and is the answer not in the manual?
Questions and answers