Download Print this page
inbody 970 User Manual
Hide thumbs Also See for 970:

Advertisement

Quick Links

User's Manual
InBody970 User's Manual for Measurement Guide and Setup
Thank you for purchasing the InBody970. This user's manual describes all the features of the InBody970.
Please read before use and keep it in a safe place. By following properly these instructions, you will be able to
use the InBody970 more safely and effectively.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 970 and is the answer not in the manual?

Questions and answers

Summary of Contents for inbody 970

  • Page 1 User's Manual InBody970 User's Manual for Measurement Guide and Setup Thank you for purchasing the InBody970. This user's manual describes all the features of the InBody970. Please read before use and keep it in a safe place. By following properly these instructions, you will be able to use the InBody970 more safely and effectively.
  • Page 2 • Sarcopenia: InBody provides a quick, easy to perform test that provides a calculation for skeletal muscle index (SMI), the sum of the lean mass in the arms and legs, normalized for height. This marker is useful in identifying low muscle in the appendages, which increases frailty risk.
  • Page 3 Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd. under the copyright laws. This manual may be printed incorrectly and subject to change without notice. InBody Co., Ltd. shall not be liable for any errors, incidental, or consequential damages that occurred by not complying with the content of the User᾽s Manual.
  • Page 5 User’s Manual Contents I. InBody Installation A. Product Components B. Installation Environment C. Installation Instructions D. Initial Setting E. Connecting External device F. Precautions for Maintenance II. InBody Test A. Precautions for Measurement B. Test Instructions C. Test Posture III. Transportation and Storage A.
  • Page 6 I. InBody Installation A. Product Components InBody970 consists of the following components. Make sure all of the following components are present. * Please check each component of the system for damage prior to installation. InBody970 ❶ Power adapter ❷ Input button Power cable ❸...
  • Page 7 B. Installation Environment Check the environment before installing the InBody970. This equipment is suitable for indoor use. If installing this equipment outdoors, the following requirements must be fulfilled. Temperature range 10 ~ 40°C (50 ~ 104°F) Relative humidity 30 ~ 75% RH Atmospheric pressure 70 ~ 106kPa C. Installation Instructions 1.
  • Page 8 • Do not clean the foot electrode and the hand electrode with detergent. If liquid cleaner flows into InBody970, it may cause corrosion and equipment failure. For cleaning the Inbody970, use an InBody tissue (wet tissue) with antibacterial effect 2. Raise the InBody970 upper section to the end and then remove the protective packaging vinyl.
  • Page 9 ❸ * The InBody970 can be connected to optional test equipment and PC program such as stadiometer, blood pressure monitor, Yscope, and LookinBody120. For details to connect, refer to "E.Connecting External Device" in "I.InBody Installation" in this user's manual. ❶...
  • Page 10 This can minimize the electric shock of the InBody970. • Use the adapter provided by InBody. The InBody970 may malfunction by using other adapters. • If you are operating the equipment in a place where the altitude is 2,000m or higher, the weight measurement may be affected.
  • Page 11 3. Enter the administrator password to set the password. This screen will appear only once for initial password setup. * Be careful not to forget the password you set. If you have forgotten your password, please contact InBody Customer Service.
  • Page 12 InBody, or A4 plain paper. 13. Outputs/Interpretations for Results Sheet : This option allows setting the items or explanations that appear on the right side of InBody Results Sheet, InBody Results Sheet for Children, and Body Water Results Sheet.
  • Page 13 PC application, or to other compatible devices such as stadiometer, blood pressure monitor, or Yscope. * For details to connect Bluetooth, please refer to "Connecting External Device" in "InBody Installation" in this User's Manual. 18. Manual/Automatic Weight : This option allows selecting whether to input weight or to measure weight when proceeding with the test after stepping up onto the footplate.
  • Page 14 04. Weight measurement seems to be inaccurate. : This option provides a checklist if the value of measured weight is thought to be abnormal. 05. The InBody Test has stopped. : This option provides a checklist if the Inbody970 test was stopped.
  • Page 15 Administrator Menu. 2) Stadiometer The height values measured by the stadiometer are sent to InBody970 when it is connected to InBody970. * Make sure to connect only InBody stadiometer. Turn off InBody970. ❶ * When InBody970 is already turned on, it may be not properly connected to the stadiometer.
  • Page 16 • Avoid laying cables connected to external devices in frequently traveled passages because individuals may trip over cables and become injured. • Do not connect external devices that are not specified from InBody to the InBody970. Otherwise, it may cause failure and malfunction.
  • Page 17 5) LookinBody By connecting LookinBody to InBody970, you can use the measurement data management function. * If LookinBody is not recognized, please contact InBody Customer Service. Turn off InBody970. ❶ * When InBody970 is already turned on, it may be not properly connected to LookinBody.
  • Page 18 7) The external device's Bluetooth ID consists of “Product Name-Serial Number”, and select the Bluetooth ID of the device to be paired and press the Connect button. * If the Bluetooth ID does not appear or the connection is not good, please contact InBody Customer Service.
  • Page 19 8) If the compatible device is registered properly, the Bluetooth ID of the device connected to the Inbody970 will appear as shown below. 9) Press the Exit button to return to the test standby screen, and the Bluetooth icon and the corresponding device icon will be displayed on the upper left corner screen.
  • Page 20 Once InBody970 is connected to the Internet, you can use it to connect with cloud services or LookinBody. * If the cloud service does not work or if LookinBody is not recognized, please contact InBody Customer Service. 1) Connecting LAN In the test standby screen without anybody on the foothold, press [Administrator Menu] button.
  • Page 21 2) Connecting W-Fi In the test standby screen without anybody on the foothold, press [Administrator Menu] button. ❶ Enter the password to enter the Administrator Menu. ❷ Go to "16.Connect to Internet" in Setup. ❸ Press Wi-Fi and press Next button. ❹...
  • Page 22 F. Maintenance Caution Do not bend the handles of the hand electrodes or rotate them in the reverse direction beyond its limitation. • Do not extend the handles of the hand electrodes beyond its limitation. • Do not place any objects on the footplate. •...
  • Page 23 Children and people with limited mobility should be supervised or assisted when attempting to test on the InBody. • After an individual with any kind of contagious disease or infection tests on the InBody, use an InBody Tissue to •...
  • Page 24 (Measurement information is managed by phone number.) 2. Inbody970 starts weight measurement. * Be careful to put only the examinee on the equipment. It may cause a wrong weight measurement when other people lean or touch the InBody 970. 3. Connecting InBody BAND2.
  • Page 25 5. After pressing the Exit button or if InBody BAND2 is not recognized, the Inbody970 checks your fingerprint. 6. If your fingerprint is recognized, the personal information will be automatically displayed on the screen as shown below. * If recognized fingerprint is different in location of the registered fingerprint, personal information may not be loaded properly. For details, please refer to "Regarding the Equipment" in "FAQ". 7. If you press Exit on the fingerprint identification screen, you may enter your customer information (ID or mobile number). * For Professional Mode, enter your ID. * For Self Mode, enter your mobile number. 8. If you do not want to enter your ID or mobile number, you can press "Guest Test" or "Skip" button to enter only your...
  • Page 26 9. Take a test posture. * For proper test posture, refer to "C.Test Posture". * When the hand and foot electrode is recognized, the InBody test begins automatically. 10. InBody Test begins. * It will be taken 70seconds to complete the test.
  • Page 27 C. Test Posture For a proper test result, use a proper posture during the test. The armpits should not reach the torso. Keep the arms straight. If the thighs are touching each other, wear knee-short shorts to prevent the thighs from touching.
  • Page 28 III. During Transportation A. Cautions during Transportation To transport the Inbody970 safely, two people should keep the equipment in a horizontal position. B. Repacking Instructions Do not transport the InBody970 as much as possible once the it has been installed. If you need to transport the InBody970, transport after repackaging it in the following order.
  • Page 29 After sealing it, transport only by holding the handle. Caution • When repacking the equipment, the protective packaging materials provided by InBody must be used. C. Transportation and Storage Environment InBody970 should be transported or stored under the following conditions.
  • Page 30 Insert the power cord completely into the adapter. The problem may occur if you are using the power adapter that is not provide • by InBody. Always connect a power adapter (DC 12V, 3.4A/3.34A) provided by InBody. Power adapter...
  • Page 31 If you cannot enter the Administrator Menu due to touchscreen problems, • please restart the InBody. The InBody stores the last touchscreen alignment and will automatically recall the previous touchscreen settings. The InBody can also recognize if its touchscreen alignment is off screen and will automatically take the user to the calibration screen after restarting.
  • Page 32 • harmful to the body? that is not harmful to the body. The safety of the InBody has been tested and proven. The InBody products have been approved for medical use by the CE and all over the world. Many medical institutions around the world are actively using the InBody.
  • Page 33 ❶ Hand electrode: For testing, all four fingers wrap around the hand electrode to contact the surface, and the thumb touches the ellipse. ❷ Fingerprint recognition sensor: Recognizes fingerprint of the left thumb and save or load the personal information automatically. InBody BAND2 recognition sensor: Receives personal information in wireless connection with InBody BAND2. ❸ Body: Connects upper section and the lower section. ❹ LCD display: It displays each step of test, guide, and test result. It enables to enter the data required for the test, set ❺...
  • Page 34 2. Footplate Front sole electrode: The examinee makes contact with this electrode by stepping with the front part of their foot. ❶ Rear sole electrode: The examinee makes contact with this electrode by stepping with the heel of their foot. ❷...
  • Page 35 Blood Pressure Monitor 9-pin serial terminal (Female, RS-232C): Used to connect InBody970 with a blood pressure ❼ monitor. * Make sure to connect only InBody blood pressure monitor. Power jack: Used to connect a power adapter. ❽ * Use the adapter provided by only InBody.
  • Page 36 B. Safety Information Indicators 9-pin serial port (Female, RS-232C) LAN port (10T Base) USB port Safety Symbols Dangerous High Voltage Warning, Caution BF Type Equipment Adapter Power On Power Off Etc. Symbols European Conformity Serial number 1639 Manufacturer Direct current Authorized representative in the Operating instructions EUROPEAN COMMUNTY...
  • Page 37 Right Leg, Left Leg) • ECW Ratio Analysis (ECW Ratio) • Body Composition History (Weight, Skeletal Muscle Mass, Percent Body Fat, ECW Ratio) • InBody Score • Visceral Fat Area (Graph) • Weight Control (Target Weight, Weight Control, Fat Control, Muscle Control) •...
  • Page 38 Metabolic Rate, Waist-Hip Ratio, Waist Circumference, Visceral Fat Level, Visceral Fat Area, Obesity Degree, Bone Mineral Content, Body Cell Mass, Arm Circumference, Arm Muscle Circumference, FFMI, FMI, SMI, recommended calorie intake per day, Calorie Expenditure of Exercise, InBody Score), Skeletal Muscle Mass/ Weighr, Extracellular Mass/Body Cell Mass, Total Body Water/Weight) •...
  • Page 39 * Blood pressure information can only be printed when the blood pressure monitor is connected. * Visceral Fat Results Sheet can be printed always from the InBody, except the main results related to abdominal part are shown when Yscope is measured.
  • Page 40 Recognizing the measurer's fingerprint, enter personal information automatically in the Inbody970. Recognition Function Backup Data Scanning QR codes send and verify the results of the InBody examination to the results management website (InBodyCare). Scanning QR codes send and verify the results of the InBody examination to the results management website QR Code (InBodyCare).
  • Page 44 1639 ⓒ2021 InBody Co., Ltd. All rights reserved. IM-ENG-I4-B-210916...