IHP Comfort Flame Columbus Series Installation And Operation Instruction Manual

Advertisement

Quick Links

P900480-00
P/N 900480-00 Rev. A 10/2015
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with UL127
CAN/ULC-S610-M87 standard as a FACTORY
BUILT FIREPLACE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard .
An IHP hood must be installed when using a vent-free log heater (see Accessories, page 19).
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a permit.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace
system. Please read and understand these instructions before beginning your
Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of
the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the
warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE
AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
INSTALLATION AND OPERATION
INSTRUCTIONS
Comfort Flame™ Columbus Series
Wood burning Fireplace
Columbus36RWS
PFS
®
C
US
REPORT NO. 10-078
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
MODELS
Columbus36LWS
installation.

Advertisement

Table of Contents
loading

Summary of Contents for IHP Comfort Flame Columbus Series

  • Page 1 ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard . An IHP hood must be installed when using a vent-free log heater (see Accessories, page 19). FOR CANADA: The authority having jurisdiction POUR LE CANADA: L’autorité...
  • Page 2: Table Of Contents

    Do not poke or stir the logs while • The IHP warranty will be voided by and IHP disclaims any respon- they are burning. Use only firelogs that have been sibility for the following actions.
  • Page 3 SAFETY Continued WARNING: CONTINUED OVERFIRING CAN PER- WARNING: BURNING IMPROPER FUEL (I.E. MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. CHARCOAL) CAN RESULT IN CARBON MONOXIDE SOME EXAMPLES OF CONDITIONS THAT COULD POISONING, WHICH MAY LEAD TO DEATH! CAUSE OVERFIRING ARE: Carbon Monoxide Poisoning – Early signs of carbon monoxide poisoning resemble the flu with headaches, • BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCHES, PAPER OR CARDBOARD BOXES...
  • Page 4: Specifications

    SPECIFICATIONS GAS LINE RIGHT SIDE KNOCK ELECTRICAL OUTLET OUTS 1" AIRSPACE TO COMBUSTIBLE MATERIAL 0" TO NO COMBUSTIBLE " MATERIAL ON FACE " SPACERS " " AIR KIT " KNOCK OUT LEFT SIDE GAS LINE KNOCK COMBUSTIBLE OUTS WALL BOARD "...
  • Page 5: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION To determine safest and most efficient location for fireplace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where fireplace will not be affected by drafts, air conditioning ducts, windows or doors.
  • Page 6 FIREPLACE INSTALLATION Continued *Note: Drawing Not To Scale WARNING: Hearth extension is to be installed Combustible " Ref. only as shown in Figure 3. Material Safe Zone For 6" Projection of Ref. Combustible 33° Materials Seal Gap Fireplace Front Non Combustible 3"...
  • Page 7: Venting Installation

    See accessories, page 19 for Kit F2659. An IHP chimney system consists of 12", 18", 24", 36" and 48" snap- lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in lineal gain chart (see Figure 8, page 8).
  • Page 8 VENTING INSTALLATION Continued ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY WARNING: The opening in collar around chimney SYSTEM at top of fireplace must not be obstructed. Never use Each double wall chimney section consists of a galvanized outer blown insulation to fill chimney enclosure pipe, a stainless steel inner flue pipe and a wire spacer.
  • Page 9 VENTING INSTALLATION Continued Return Elbow Return Elbow Return Elbow Offset Offset Elbow 6' Max. 6' Max. Elbow Ceiling Support Pipe Return 6' Max. 12S-8DM Elbow 6' Max. Return Offset Offset Elbow Elbow Offset Elbow 6' Max. 6' Max. Elbow Figure 9 - Typical Offset Installation See Detail A Ceiling Support Pipe 12S-8DM...
  • Page 10 VENTING INSTALLATION Continued If area above is a living space, install firestop OFFSET RISE CHIMNEY LENGTH below framed hole. 48" 36" 24" 18" 12" " " ELBOW SET ONLY 9" " " 31" 15" " " " 20" " " "...
  • Page 11 VENTING INSTALLATION Continued Storm Collar Installation (SC1) Minimum Measurements Place storm collar over pipe and slide down until it is snug against " open edge of flashing (see Figure 16). Use SC1 for all round termina- (48.3 cm) 30" tions. Apply waterproof caulk around perimeter of collar to provide 1"...
  • Page 12 VENTING INSTALLATION Continued CHASE INSTALLATIONS Level of Instructions for chase installations are included with chase style ter- Flue Gas mination chosen. In a multiple chase installation, be sure to provide Outlet adequate distance between terminations to prevent smoke spillage 2' Min. from one termination to another.
  • Page 13: Optional Gas Line Installation

    Creosote will ignite if heavily heated. Note: An IHP hood must be installed when using an unvented gas log set (see Accessories on page 19). WARNING: When using a decorative vented gas...
  • Page 14: Operation And Maintenance

    IMPORTANT: The glass must be allowed to warm slowly and evenly. Tempered glass will withstand a gradual temperature rise to 550° WARNING: Risk of fire! Replace grate with IHP F, which is more than a normal fire will generate. Such materials as model 109910-01 only.
  • Page 15: Replacement Parts

    Sheet metal cover plates located underneath front hearth refractory may have shifted or moved out of place while fireplace was in transit. These Normally, all parts should be ordered through your IHP distributor cover plates must be kept in the proper location prior to using the fireplace or dealer.
  • Page 16: Parts

    PARTS WOOD BURNING FIREPLACE MODELS: CAT NO. MODEL F2541 Columbus36RWS F2542 Columbus36LWS 34/35 Comfortflame.US.com 900480-00A...
  • Page 17 This list contains replaceable parts used in your fireplace. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards.
  • Page 18: Accessories

    ACCESSORIES BI-FOLD GLASS DOORS CAT NO. MODEL DESCRIPTION F0981 BD36 36" Standard Bi-Fold Glass Door - Black finish F0982 BD36B 36" Standard Bi-Fold Glass Door - Brushed Brass finish F0983 BD36P 36" Standard Bi-Fold Glass Door - Platinum finish DOUBLE WALL PIPE F0895 12-8DM 12"...
  • Page 19 ACCESSORIES Continued ANTI-DRAFT SHIELD (Round Top Termination Only) F0927 ADS-8DM Anti-Draft Shield for Round Top Only MESH ROUND TOP TERMINATIONS F0916 RT-8DM Round Top with Mesh Screen F0888 RT-8HT Hi-Temp Round Top with Mesh Screen MESH ROUND TOP TERMINATIONS WITH SLIP SECTION F0917 RTT-8DM Round Top with Slip Section &...
  • Page 20 Wood burning Chimney facturer. A locally fabricated MUST BE MAINTAINED. F0881 12-8HT 12" Section Hi-Temp Double shroud may be used with IHP Wall Pipe Snap Lock WARNING: DO NOT INSTALL Shroud Leg Spacer Kit (SLK) F0882 18-8HT 18" Section Hi-Temp Double...
  • Page 21 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ 900480-00A Comfortflame.US.com...
  • Page 22 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ Comfortflame.US.com 900480-00A...
  • Page 23: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108;...
  • Page 24 Consult your local distributor for fireplace code information. P900480-00 Printed in U.S.A. © 2015 IHP LLC 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210 P/N 900480-00 Rev. A 10/2015.

This manual is also suitable for:

Comfort flame columbus36rwsComfort flame columbus36lws

Table of Contents