IHP Superior DRT4036TEN Manual

Direct-vent gas fireplace

Advertisement

Quick Links

Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 126721-02
P/N 126721-01 Rev D
P126721-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
PFS
06/2016
C
Report No. F09 -099
Installation and Operation Instructions
Superior
Direct-Vent Gas Fireplace
®
Models
DRT4036TEN
®
DRT4042TEN
US
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation
ultérieure.
AVERTISSEMENT
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pourrait
d'entraîner des blessures graves, la mort ou des dom-
mages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage de
cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
DRT4036TEP
DRT4042TEP

Advertisement

Table of Contents
loading

Summary of Contents for IHP Superior DRT4036TEN

  • Page 1 Installation and Operation Instructions Superior Direct-Vent Gas Fireplace ® Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 126721-02 DRT4036TEN DRT4036TEP ® P/N 126721-01 Rev D 06/2016 DRT4042TEN DRT4042TEP Report No. F09 -099 P126721-01 INSTALLER: Leave this manual with the appliance.
  • Page 2: Safety And Your Fireplace

    SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTREMELY HOT! EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  To prevent severe burns  Afin d’éviter les brûlures  Para evitar quemaduras y lesiones...
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de importante tion seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked, si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 5: Table Of Contents

    This vented gas fireplace is a sealed combustion gas fireplace de- signed for residential applications. This fireplace must be installed This appliance is only for use with the type of gas with INNOVATIVE HEARTH PRODUCTS (IHP) vent pipe components indicated on the rating plate. This appliance is not and terminations.
  • Page 6 SAFETY Continued Carbon Monoxide Poisoning: Early signs of carbon monoxide poison- Installation and repair should be done by a qualified ing resemble the flu, with headaches, dizziness or nausea. If you have service person. The appliance should be inspected these signs, the fireplace may not be working properly. Get fresh air before use and at least annually by a professional at once! Have fireplace serviced.
  • Page 7: Local Codes

    SAFETY Continued LOCAL CODES 6. Have venting system inspected annually by a qualified service Install and use fireplace with care. Follow all local codes. In the person. If needed, have venting system cleaned or repaired. See absence to local codes, use the current National Fuel Gas Code ANSI Cleaning and Maintenance, page 27.
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts Horizontal Vent Requirements These appliances are approved for installation in the US state of In the Commonwealth of Massachusetts, horizontal terminations Massachusetts if the following additional requirements are met: installed less than seven (7) feet above the finished grade must comply with the following additional requirements: •...
  • Page 9 PRE-INSTALLATION Continued " (740 mm) 36" Model " (883 mm) 42" Model Requires IHP 5" (127 mm) I.D. 8" (203 mm) O.D. Direct-Vent Pipe " (302 mm) 36" Model " (346 mm) 42" Model " (521 mm) 36" Model 24" (610 mm) 42"...
  • Page 10 PRE-INSTALLATION Continued CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: *Back and sides 1" (26 mm) Perpendicular walls 6" (153 mm) 44" (1118 mm) Floor 0" (0 mm) 36" Model Ceiling to louver opening 42" (1067 mm) 48"...
  • Page 11: Location Of Termination Cap

    LOCATION OF TERMINATION CAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) I = clearance to service regulator vent outlet [*72" (182.9 cm) A = clearance above grade, veranda, porch, deck, or balcony [*12"...
  • Page 12: Venting Installation

    The venting system must NEVER be attached to a chimney serving These models are tested and approved for use with an IHP (direct a separate solid fuel burning appliance. Each direct vent) pipe components and terminations.
  • Page 13 VENTING INSTALLATION Continued 5. Noncombustible Exterior Wall: Position horizontal vent cap in center of the 8 " round hole and attach to exterior wall with four wood screws Female Locking provided. Before attaching vent cap to exterior wall, run a bead of non- Lugs hardening mastic (pliable sealant) around outside edges to make a seal between it and outside wall.
  • Page 14 VENTING INSTALLATION Continued Horizontal Termination Configurations Cut Siding Away to Fit Figure 15 shows a configuration for venting with horizontal termi- Standoff nation with a chart of critical minimum and maximum dimensions which MUST be met. Standoff Wood Figure 16, page 15, shows a configuration for venting with horizontal Screw termination using two 90°...
  • Page 15 VENTING INSTALLATION Continued 2. Assemble desired lengths of pipe and elbows necessary to reach from fireplace flue up through firestop. Be sure all pipe and elbow connections are fully twist-locked (see Figure 9, page 13). 3. Cut a hole in the roof using locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 11 "...
  • Page 16 Figure 20 - Vertical Venting Configuration Using Two 90° Elbows HIGH ALTITUDE INSTALLATION Your IHP direct vent fireplace has been tested and approved for elevations from 0-2000 feet. Figure 18 - Installing Firestop When installing a fireplace at an elevation above 2000 feet, you may...
  • Page 17: Fireplace Installation

    FIREPLACE INSTALLATION CHECK GAS TYPE IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting Use proper gas type for the fireplace unit you are installing. If you off the gas to the appliance.
  • Page 18 FIREPLACE INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY WARNING: Use pipe joint sealant that is resistant Installation Items Needed to liquid petroleum (LP) gas. • 5/16" hex socket wrench or nut-driver We recommend that you install a sediment trap/drip leg in supply line •...
  • Page 19 FIREPLACE INSTALLATION Continued REMOVING/REPLACING GLASS DOOR Equipment Shutoff Valve CAUTION: Do not operate this fireplace with a bro- Propane/LP ken glass door panel or without the glass door panel Supply Tank securely in place. For replacement part information see Replacement Parts, page 31. CAUTION: Wear gloves and safety glasses while handling or removing broken glass.
  • Page 20 FIREPLACE INSTALLATION Continued Replacing Glass Door 3. Place volcanic stone around base of burner. Make sure burner ports are not covered (see Figure 30, page 21). 1. Position door frame in front of firebox opening with bottom of 4. Place ember flakes around front and sides of burner and on burner door tilted away from firebox (see Figure 27, page 19).
  • Page 21 FIREPLACE INSTALLATION Continued To Gas Supply Volcanic stone Equipment (Natural) Shutoff Valve Control Valve To External Regulator (Propane/LP) Flexible Gas Line, Do NOT Kink Figure 30 - Installing Volcanic stone Figure 33 - Connecting/Disconnecting Gas Line to Control Valve WARNING: Never use an open flame to check for a leak.
  • Page 22 FIREPLACE INSTALLATION Continued GAS CONTROL MODULE SYSTEM Learn Button AUX Connection The module has 2 special features built into the system. CONTINUOUS PILOT FEATURE This allows the change from a spark to pilot system to a standing pilot system. There is a switch located on the right side of the module that reads CONTINUOUS PILOT ON/OFF.
  • Page 23: Installer - Attaching Safety In Operation Warnings

    (Figure C). Choisissez la langue qui est cuál es, use la etiqueta en inglés. contact IHP or your nearest IHP dealer to receive principalement parlée dans la résidence du proprié- 3. Si usted es incapaz de localizar las etiquetas, por favor additional safety instruction labels free of charge.
  • Page 24: Operation

    OPERATION FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS NOTICE: During initial operation of new fireplace, burn- WARNING: If you do not follow these instructions ing logs will give off a paper-burning smell. Orange exactly, a fire or explosion may result causing property flame will also be present.
  • Page 25: Homeowner's - Attaching Safety In Operation Warnings

    Collez l’étiquette sur le boîtier de la télécommande 3. Si usted es incapaz de localizar las etiquetas, por favor contact IHP or your nearest IHP dealer to receive (Figure C). Choisissez la langue qui est principale- póngase en contacto con IHP, o con su distribuidor additional safety instruction labels free of charge.
  • Page 26: Inspecting Burners

    INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. BURNER FLAME PATTERN Burner flames will be steady, not lifting or floating. Flame patterns will PILOT ASSEMBLY be different from unit to unit and will vary depending on installation The pilot assembly is factory preset for the proper flame.
  • Page 27: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before CAUTION: Do not vacuum if pieces are hot. cleaning. Use only glass door replacement intended for this fireplace (see Replacement Parts, page 37 for detail on ordering). No substitutions CAUTION: You must keep control areas, burners may be made.
  • Page 28: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 29 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately •...
  • Page 30: Parts

    PARTS MODEL CATALOG NO. DESCRIPTION MODEL CATALOG NO. DESCRIPTION DRT4036TEN F1322 36"V Natural HER Red Brick DRT4036TEN F2280 36"V Natural HER White Brick DRT4036TEP F1323 36"V Natural STK Red Brick DRT4036TEP F2281 36"V Natural STK White Brick DRT4036TEN F1324 36"V Propane HER Red Brick DRT4036TEN F2282 36"V Propane HER White Brick...
  • Page 31 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards.
  • Page 32 PARTS WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. AVERTISSEMENT. Risque de dommages ou de blessures si les pièces ne sont pas installées confor- mément à...
  • Page 33 37 of this manual. This table uses catalog numbers for clarity on models. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards.
  • Page 34 PARTS REFRACTORY PARTS MODEL CATALOG NO. DESCRIPTION MODEL CATALOG NO. DESCRIPTION DRT4036TEN F1322 36"V Natural HER Red Brick DRT4036TEN F2280 36"V Natural HER White Brick DRT4036TEP F1323 36"V Natural STK Red Brick DRT4036TEP F2281 36"V Natural STK White Brick DRT4036TEN F1324 36"V Propane HER Red Brick DRT4036TEN...
  • Page 35 PARTS REFRACTORY PARTS CATALOG DESCRIPTION QTY. J7791 Rear Refractory, Herringbone 42" Red • J7792 Rear Refractory, Herringbone 36" Red • J7793 Rear Refractory, Stacked 42" Red • J7794 Rear Refractory, Stacked 36" Red • J7795 Left Refractory, Herringbone 42" Red •...
  • Page 36: Specifications

    SPECIFICATIONS DRT4036TEN DRT4036TEP • Rating: 33,500 Btu/hr • Rating: 31,000 Btu/hr • Gas Type: Natural Gas Only • Gas Type: Propane/LP Gas Only • Ignition: Electronic • Ignition: Electronic • Manifold Pressure: 3.5" w.c. • Manifold Pressure: 10" w.c. • Minimum Inlet Supply Pressure: 5" w.c. •...
  • Page 37: Technical Service

    See Pages 30 to 35 for a complete replacement parts list. Use only parts supplied from the manufacturer. Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order.
  • Page 38 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ Superiorfireplaces.US.com 126721-01_D...
  • Page 39: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the distributor, then you must notify IHP in writing.
  • Page 40 Superiorfireplaces.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name P126721-01 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents