IHP Astra Fireplaces Altair Series Operation Instructions Manual

Direct-vent gas fireplaces

Advertisement

Quick Links

P/N 900697-00 REV. F 06/2019
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900697-04.
P900697-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Altair™ Series Direct-Vent Gas Fireplaces
Models
Altair 40DMN-B
C
US
Altair 40DMP-B
Report No. 16-120
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Altair 40DEN-B
Altair 40DEP-B
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Altair 45DMN-B
Altair 45DEN-B
Altair 45DMP-B
Altair 45DEP-B

Advertisement

Table of Contents
loading

Summary of Contents for IHP Astra Fireplaces Altair Series

  • Page 1 Installation and Operation Instructions Altair™ Series Direct-Vent Gas Fireplaces P/N 900697-00 REV. F 06/2019 Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900697-04. Altair 40DMN-B Altair 40DEN-B Altair 45DMN-B Altair 45DEN-B Altair 40DMP-B Altair 40DEP-B Altair 45DMP-B Altair 45DEP-B...
  • Page 2: General Information

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and must be installed for the protection of children and other at-risk individuals.
  • Page 3 Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES ! EXTREMELY HOT! MUY CALIENTES!  To prevent severe burns  Para evitar quemaduras y lesiones ...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 40” Models 28,000 20,000 25,000 18,000 45”...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down regulators to reduce the pressure to safe levels. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in (Figure 6). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 6).
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Figure 7 - Mantel Height Figure 6 - Combustible Side Clearances At 6” (153 mm) mini- At 6” minimum mum side wall clear- Mantel depth side wall clearance, Top View of ance, a combustible Top View of...
  • Page 16: Installation

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 17 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 10 - Fireplace Framing Specifications **NOTE: Dimension “D” is the Framing required framing depth when construction to be 10-1/2 Model units are installed with the 2 x 4, or larger. (267) fireplace face flush to framing 40-3/4...
  • Page 18: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8). 2.
  • Page 19 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove all insulation packing and flue plug block off from rear venting and proceed with fireplace installation.
  • Page 20 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Rough in the Electrical Supply, if Needed As necessary, rough in the fireplace electrical supply per NEC and local codes. Install the [Optional] Blower Kit before Installation in the Framing 1.
  • Page 21: Vent System Preparation

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper. NOTE: Combustible framing may be in direct contact with the nailing flanges and may be located within 1/2”...
  • Page 22 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Install the Vent Restrictor (if necessary) U-Shaped Vent 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. Restrictor 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 12 and 15. U-Shaped Vent Restrictor 3.
  • Page 23 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Connecting the vent pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist ® lock connections (Figures 16-17). All of the fireplaces covered in this document are fitted with collars having locking inclined channels.
  • Page 24 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 46) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
  • Page 26 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 23-24 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 23 for more information. 8.
  • Page 28 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 29 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex , use ® ceiling firestop/ spacer SF4.5VF. Ceiling firestop/ When using spacer SV4.5VF...
  • Page 30 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 6. Install the firestop/spacer at the ceiling—When using Secure Vent , use SV4.5VF firestop/spacer at ceiling ® joists; when using Secure Flex , use SF4.5VF firestop/spacer. If there is living space above the ceiling level, ®...
  • Page 32 Telescopic vent section, Base of Appliance Elbow or Appliance Collar *Recommended IHP termination kit: H1968 **With termination kit only, 6” to 9-1/4” Installing the Horizontal Termination NOTE: To help minimize water infiltration install the firestop/spacer (SV4.5HF) on the exterior side of the wall. The firestop may be caulked with mill base caulk (such as 10K81) or high-temperature silicone.
  • Page 33 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Ceiling Min.
  • Page 35 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Wall firestop/spacer Wall Firestop/Spacer feet meters feet meters feet meters SV4.5HF ** SV4.5HF** 1.524 0.610 0.305 3.048...
  • Page 36 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent ®...
  • Page 37: Complete The Field Wiring

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent. f.
  • Page 38 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. CAUTION In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
  • Page 39: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Figure 31 - Wiring Diagram—Ecoflow Electronic Gas Valves Ecoflow Electronic Pilot Gas Valve Burner 2 Main Burner Thermocouple Ground - Connector to Chassis Ground or Valve Body Thermocouple - To “S” Valve Terminal on Main Module Step...
  • Page 40: Connect The Gas Line

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Figure 32 - Junction Box Wiring, 120 V, 60 hz, 1 phase Figure 33 - Wiring Diagram—Millivolt Gas Valves Wall-mounted ON/ THERMOPILE OFF blower switch APPLIANCE- MOUNTED or variable speed ON/OFF SWITCH (OPTIONAL) control switch...
  • Page 41: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation.
  • Page 42: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Optional: Install the Firebox Liners 1. See Page 53 for instructions on Traditional Only: Installing the Firebox Liners. Install the Logs, Volcanic Stone, and Glowing Embers 1. See Page 54 for instructions on Installing the logs, volcanic stone, and glowing embers. Install the Glass Door 1.
  • Page 43: Install The Hood

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Figure 38A - FRONT Air Shutter Setting Figure 38B - REAR Air Shutter Setting Adjustment Set-Screw Rear Air Shutter Adjustment Lever Adjustment Rod Up Burner (Fully-Closed Tube Position) Air Shutter Closed Open Adjustment...
  • Page 44: Install The Finishing Materials

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Reinstall the Included Barrier WARNING Reinstall any barrier removed before operating the fireplace. The barrier is designed to reduce the risk of burns from hot glass. Do not operate the fireplace without the barrier installed.
  • Page 45 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 46: Installation Accessories

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Table 30 - Listed Secure Vent Components ®...
  • Page 47 Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 INSTALLATION ACCESSORIES (continued) Table 31 - Listed Secure Flex Components ® Cat. No. Model Description Cat. No. Model Description Vertical Termination for flex (flat These termination kits include firestop/spacer, gear clamps, and flex adaptor. to 6/12) with flex adaptor, section 18 ft (5.49 m)* compressed flex 56L74...
  • Page 48: Gas Conversion Kits

    Innovative Hearth Products Installation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 49: Operation

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 50 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARN- APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD INGS LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- Votre foyer a été...
  • Page 51 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 52 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 If the millivolt fireplace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the fireplace main burner can be turned ON/OFF using the optional switch. NOTE: Do NOT wire more than one valve to the burner control switch.
  • Page 53 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Continuous Pilot Ignition Switch (located in the control compartment) Fireplaces with an electronic gas valve have a continuous pilot ignition (CPI) switch installed in the control compartment. This switch allows the pilot to be switched from intermittent mode to continuous mode: •...
  • Page 54 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Install the Logs, Volcanic Stone, and Glowing Embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 55 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Installing the Altair™ Series 40” and 45” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 56 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 5. Place the middle left log #4 (Figure 54) on the setting pins in the middle of the grate (Figure 50). 6. Place the front left forked log #5 over log #4 as shown in Figure 55. One foot will rest between the 2nd and 3rd bar from the left on the grate.
  • Page 57 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 58 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 59: Maintenance

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 60 Touching up paint in small areas Only use a factory-supplied paint kit for any touch-ups. Paint is available at your local IHP dealer. Never attempt to paint a hot fireplace. Do not attempt to repaint the fireplace until the finish is completely cured (Burn-in Period on Page 51).
  • Page 61 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating.
  • Page 62: Accessory Components

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 ACCESSORY COMPONENTS Forced Air Kits The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation. The FBK-250 offers variable speed control and a heat-activated switch;...
  • Page 63 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 ACCESSORY COMPONENTS (continued) ON/OFF and Timer Control Kits (Millivolt Models) Feature a timed ON/OFF mode as well as manual ON/OFF operation. Cost Effective Solution Catalog Number • Manual ON/OFF operation F2236 •...
  • Page 64: Lighting Instructions

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 65 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 66 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 67 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 68: Troubleshooting

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 69 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 TROUBLESHOOTING ELECTRONIC SYSTEMS SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Nothing happens a. Remote is not functioning properly. Operate the fireplace from the unit-mounted On/Off when the fireplace is switch. turned ON/OFF.
  • Page 70: Replacement Parts

    Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 REPLACEMENT PARTS 40” Models 45” Models Catalog Number Catalog Number Millivolt, Pilot Assembly, Natural Gas 69L17 69L17 Millivolt, Pilot Assembly, Liquid Propane 69L18 69L18 Millivolt Piezo Igniter 10K86 10K86 Millivolt Piezo Igniter Wire 56L21 56L21...
  • Page 71 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 REPLACEMENT PARTS (continued) 40” Models 45” Models Catalog Number Catalog Number ECOFLOW PARTS --- Pilot Assembly, Ecoflow, Natural Gas J7935 J7935 --- Pilot Assembly, Ecoflow, Liquid Propane J7962 J7962 --- Gas Valve, Ecoflow, Natural Gas J7936 J7960...
  • Page 72 Innovative Hearth Products Operation Altair™ Series Direct-Vent Gas Fireplaces 900697-00F 06/2019 REPLACEMENT PARTS (continued) Cat. No. Model Description F2644 Altair40DMN-B 40” DV, MV, Black Interior, NG F2645 Altair40DMP-B 40” DV, MV, Black Interior, LP F2646 Altair40DEN-B 40” DV, Elec, Black Interior, NG F2647 Altair40DEP-B 40”...
  • Page 73: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street;...
  • Page 74 Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.