Advertisement

P/N 775218M REV. G 01/2015
A French manual is available upon
request. Order P/N 775218CF.
Ce manuel d'installation est disponible
en francais, simplement en faire la
demande. Numéro de la pièce 775218CF.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Ravenna™
C
US
Report # 14-164
This fireplace insert is factory equipped for 40,000 BTU input and can be converted to
33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas
or P/N H5925 for Propane Gas).

INSTALLATION AND OPERATION

MODELS
RDV33/40
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P775218M
SDVI33/40

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ravenna RDV33 and is the answer not in the manual?

Questions and answers

Summary of Contents for IHP Ravenna RDV33

  • Page 1: Installation And Operation

    INSTALLATION AND OPERATION Direct-Vent Ravenna™ P775218M P/N 775218M REV. G 01/2015 A French manual is available upon MODELS request. Order P/N 775218CF. Report # 14-164 Ce manuel d’installation est disponible en francais, simplement en faire la RDV33/40 SDVI33/40 demande. Numéro de la pièce 775218CF. This fireplace insert is factory equipped for 40,000 BTU input and can be converted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or P/N H5925 for Propane Gas).
  • Page 2: Safety And Your Fireplace Insert

    SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable chimenea Fireplace Insert All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT...
  • Page 4: Table Of Contents

    Pre-Lighting Checklist ........20 your new gas fireplace insert. Lighting Instructions .........20 Thank you for selecting an IHP gas fireplace insert as the answer Flame Color and Behavior ........22 to your home heating needs. Paint Curing ...........22 Quiet Operation ..........22...
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    Collez l’étiquette sur le boîtier de la télécommande 3. Si usted es incapaz de localizar las etiquetas, por favor contact IHP or your nearest IHP dealer to receive (Figure C). Choisissez la langue qui est principale- póngase en contacto con IHP, o con su distribuidor additional safety instruction labels free of charge.
  • Page 7: Installer - Attaching Safety In Operation Warnings

    (Figure C). Choisissez la langue qui est cuál es, use la etiqueta en inglés. contact IHP or your nearest IHP dealer to receive principalement parlée dans la résidence du proprié- 3. Si usted es incapaz de localizar las etiquetas, por favor additional safety instruction labels free of charge.
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     IHP, its employees, or any of its representatives assume no responsibility for any damages caused by an inoperable, inad-  C learances are in accordance with local installation codes and equate, or unsafe condition as a result of any improper operation, the requirements of the gas supplier.
  • Page 10: Orifice Size/Altitude Adjustment

    Improper orifice sizing may result in damage and unsafe circulator). conditions. Changing the orifice should only be done by a qualified service technician. Contact your IHP dealer for proper orifice sizes. CAUTION In Canada - CAN/CGA-2.17-M91 (R2009) (high altitude): •...
  • Page 11: Codes And Approvals

    If there are any questions or if you • The individual manual shut-off must be a T-handle type valve. need further substantiation contact your IHP dealer. If you have further questions, please contact IHP. Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts, horizontal terminations installed Check all local building and safety codes before installation.
  • Page 12: Pre-Installation

    This appliance comes from the factory equipped to burn natural gas at a specified elevation. Only IHP conversion kits can be used to convert from NG to LP or LP to NG. Contact your IHP dealer for details. RATINGS RDV40 / SDVI40...
  • Page 13: Insert And Fireplace Dimensions

    Minimum Fireplace Cavity Insert Dimensions 31-1/4” (794mm) Top View 13-3/4” 15-3/4" (349mm) (400mm) 15-3/4" Figure 3 (400mm) Minimum Fireplace Opening 19-1/2" 31-1/2" (800mm) Front Opening (495mm) 19-1/2” (495mm) Height 19-3/4 18” (457mm) Rear Width (502mm) 16” (406mm) Fireplace Depth * Top air duct will need to be removed for short ZC applications. Replace tap tights when removed.
  • Page 14: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES 3"/76mm 3"/76mm IMPORTANT: If unit is converted to an RDV33 / SDVI33 from 3"/76mm 3"/76mm an RDV40 / SDVI40, the clearances to combustibles can be 3"/76mm 3"/76mm reduced as shown on this page. 1-1/2” RDV40 / SDVI40 1-1/2”...
  • Page 15: Installation

    NOTE: The minimum vertical rise (exhaust vent) is 10 feet (3.1 M) and INSTALLATION the maximum vertical rise is 35 feet (10.7 M). These dimensions are measured from the starting collars of the unit to the end of the vent pipe. Venting Installation The fireplace and fireplace chimney must be clean and in good working Your appliance must be vented to the outside in accordance with the...
  • Page 16: Zero Clearance Fireplace Installation

    Zero Clearance Fireplace Installation This appliance may be installed in a masonry or factory built/zero clear- ance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. The 2 Screws ZC doors, screen, refractory or masonry lining, baffles and smoke shelf may be removed if necessary to install the gas insert.
  • Page 17: Surround Panels Installation (Required Accessory)

    4. Install a light layer of glowing embers (rockwool) directly over the ports. 1. Remove the speed nuts (A in Figure 13) from the parts bag and - A light layer will give a more constant rear flame. install (with the flat surface forward) on the six holes in the surround - A heavy layer will give more glow, but will need to brackets - three on each side of the insert (B in in Figure 13).
  • Page 18: Gas Line Installation

    This appliance can only be operated using propane gas (LP) if a page for gas pressure requirements. certified fuel conversion kit provided by IHP is installed by a qualified Two pressure taps are provided on the appliance's valve to check gas service technician.
  • Page 19 Moving shutter bracket to the right will open shut- ter, to the left will close shutter. Shutter Adjustment Detail SHUTTER ADJUSTMENT DETAIL Figure 15b See Detail Shutter Adjustment Figure 15a NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 20: Operating Instructions

    4. Open the lower door to access control compartment. Make sure gas supply shut-off cocks are open. CAUTION: YOUR IHP GAS APPLIANCE MUST ALWAYS BE OPER- ATED WITH GLASS IN PLACE. 5. Push in gas cock dial slightly and turn clockwise "OFF."...
  • Page 21 9. Push in control knob all the way and hold in. Immediately light WARNING the pilot by triggering the piezo igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about • Operation of this appliance when not connected 1-1/2 minutes after the pilot is lit.
  • Page 22: Flame Color And Behavior

    Flame Color and Behavior Quiet Operation This appliance is designed for maximum heating efficiency. Therefore, As the appliance is burning, a number of normal operational sounds may upon lighting of the main burner the flames will be semi-transparent or be heard. The flow of gas through the gas valve and orifice may make a “bluish.”...
  • Page 23: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length The rocker switch on your gas appliance is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole 12 Gage 100 Feet in the right side of the top surround panel or in the hole in the panel to 14 Gage...
  • Page 24: Maintenance And Servicing

    o Check that the area around the insert is kept clear and is free of MAINTENANCE AND SERVICING combustible materials, gasoline and other flammable vapors and liquids. o Check the millivolt system as per the table on this page. WARNING 2.
  • Page 25: Glass Maintenance

    This replacement glass door is available from your IHP dealer. Do not use substitute parts or materials. The glass is neo-ceramic and alternative types must not WARNING be used.
  • Page 26: Fuel Conversion

    Electrical Requirements: Fuel Conversion Converting this appliance between natural gas and LP can be accomplished This gas appliance operates without an outside power source, however by installing a conversion kit (valve regulator and burner orifice). Only a the blower requires a 120 Volt electrical service outlet. This appliance, when installed, must be electrically grounded in accordance with local qualified service technician should perform the conversion.
  • Page 27: Replacing A Damaged Barrier

    Replacing A Damaged Barrier • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier Part No. J7510 (Contemporary Facade) or J7511 (Cast Pillar Facade). Follow installation instruc- tions.
  • Page 28: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 29: Replacement Parts

    Contact an IHP dealer to obtain any of these parts. Please contact IHP REPLACEMENT PARTS - RDV33/40 AND SDVI33/40 for the phone number of your nearest IHP dealer. Cat. No. Description WARNING H3132 Cassette Assembly NG 33,000 BTU (if LP, also requires H5433 Never use substitute materials.
  • Page 30: Accessories

    ACCESSORIES - RDV33/40 AND SDVI33/40 Gas Conversion Kits Product Reference Information Cat. No. Description Ship. Ship. Weight Volume H5433 RDV-CK-NG to LP Conversion Kit 33/40 NG to LP (ref. form #775247M) H6967 RAV33/40DVI-C, Direct-Vent Gas Fire- 136 lb. 17.76 cu. ft. H5434 RDB-CK-LP to NG Conversion Kit 33/40 LP to NG (ref.
  • Page 31 ACCESSORIES - RDV33/40 AND SDVI33/40 Pillar Cast Face Kits NOTE: 3 boxes to complete face Surround Trim Kits 37-5/8" W x 23-3/4" H (ref. form #775262M) H5143 GFT2941-B Trim/Black 29" x 41" F2324 PILCST-GLASS-BARRIER Cast Door (Box 1 of 3) (ref.
  • Page 32: Accessories

    ACCESSORIES - RDV33/40 AND SDVI33/40 Cost Effective Solution • Simple On/Off operation • Works with millivolt and low voltage electronic ignition controls Flame and Heat modulation Kit includes: Remote and Receiver • Includes solenoid for SIT millivolt valves • Thermostatic, manual or up to 9 hour Count- G-Fire Remote, Simple On/Off Thermostatic or Manual modes down Timer modes...
  • Page 33: Insert Labels

    SAFETY / LISTING LABEL - RDV33/40 AND SDVI33/40 SERIAL SERIAL Le numéro de série est indiqué dans la MODÈLE Ravenna™ MODEL Ravenna™ section anglophone de cette étiquette FABRIQUÉ PAR: MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS INNOVATIVE HEARTH PRODUCTS Rapport nº 14-164 Report No.
  • Page 34 LIGHTING LABEL - RDV33/40 AND SDVI33/40 POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque property damage, personal injury or loss of life.
  • Page 35: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP distributor, then you must notify IHP in writing.
  • Page 36: Product Reference Information

    Fuel Type (Check one) c Natural Gas c Propane Gas (LP) IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, and prices, and also to discontinue colors, styles, and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

Ravenna rdv40Ravenna sdvi33Ravenna sdvi40

Table of Contents