Troubleshooting; Specifications; Compliance With Standards - QOLSYS IQ Dimmer-PG Installation Manual

Table of Contents

Advertisement

Troubleshooting

WARNING: The wiring should only be changed in accordance with applicable electrical codes
and regulations in your region.
WARNING: Only a qualified professional should attempt to change electrical wiring.
Light does not dim, has poor dimming range, or they flicker or buzz.
The light is not compatible with the dimmer. Check with the light manufacturer to ensure that
the light is compatible with dimmers.
Light flickering
The light needs a better connection.
Wires need to be firmly secured under the terminal screws of the dimmer.
Light does not turn on and LED indicator does not turn on
Check if the circuit breaker or fuse has tripped.
Check if the light is burned out.
The light neutral connection is not wired.
Unable to control the lights remotely
Check if the IQ Dimmer PG is connected to the IQ Panel and ensure the wiring is correct.

Specifications

Frequency range
Communication protocol
Power supply
Maximum load
Standby power consumption
Maximum current
Wiring
Humidity
Operational temperature
Storage temperature range
Device weight

Compliance with standards

FCC and ISED Canada Compliance Statement
This device complies with FCC Rules Part 15 and with ISED license-exempt RSS standard(s).
Operation is subject to two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
that may be received or that may cause undesired operation.
912-919MHz
PowerG
120V at 60Hz
Incandescent 200W, CFL/LED 100W
<1W
1.67A
Terminal block connection, wire gauge16-10
AWG
0% to 85%, non condensing
0°C to 40°C or 32°F to 104°F
-20°C to 60°C or -4°F to 140°F
137g
D-308962 IQ Dimmer-PG Install Guide