Installing The Device - QOLSYS IQ Dimmer-PG Installation Manual

Table of Contents

Advertisement

Table 1: Device overview
Callout
1
2
3
4

Installing the device

WARNING: Before installing the device, make sure that the electricity supply to the area is
turned off. Failure to do so may result in electric shock or serious injury.
1.
Turn the power off at the circuit breaker.
2.
Remove the existing dimmer and connect the new dimmer according to Figure 2 and Figure
3.
Note: Pull the air gap out of the dimmer.
Figure 2: Wiring diagram
Figure 3: Connecting the new dimmer
Callout
1
2
3
4
5
6
2
IQ Dimmer-PG Installation Guide
Name
Dim up
Status LED
Air gap
Dim down
Ground
Load
Not used
Line
Line/Hot
Neutral
120V~
60Hz
Neutral
Terminal screw marked green
Terminal screw marked black
Line wire colored black
Neutral wire colored white
Ground wire colored green
Load wire colored red
D-308962 IQ Dimmer-PG Install Guide
Load