Chapter 5 Startup, Shutdown and Maintenance
5.4 Warm-up Operation
If the LED display has been idle for 14 days, perform warm-up operations before
using the LED display.
Set the prestored picture as follows when you initially start the LED display. This
setting is for warm-up operation only. You do not need to set the prestored picture if
the LED display is used frequently.
5.4.1 Unilumin N series - Setting the Prestored Picture
For details about how to set the prestored picture, refer to Section 3.6. Select a
black background picture. Set Boot Screen to 60 seconds. Set both Cable
Disconnect and No DVI Signal to Prestored Picture. Then click Save to Hardware.
See Fig 5-1.
84
Unilumin
Fig 5-1: Prestore Picture Setting