SERVICE FAULT/ERROR CODES

CODE
DESCRIPTION
F1E1
Motor or Heater Fault
F2E1
HMI stuck button
F3E1
Exhaust Thermistor
Open/Shorted
F3E2
Moisture Sensor
Open/Shorted
F6E1
Communication Error: HMI and ACU
FOR SERVICE TECHNICIAN'S USE ONLY
EXPLANATION AND RECOMMENDED PROCEDURE
1.
See Test #3: Motor Circuit
2.
See Test #4: Heat System
Indicates a stuck button (depressed for over 20 seconds).
See Test #6: HMI,
Indicates that the exhaust thermistor is open or shorted. If the Open/Shorted temperature
drops below 18
is above 250
the J14 connector is not plugged into the ACU. See TEST #4a: Thermistor,
Indicates the moisture sensor strip is open or shorted. This fault code will only appear
when in the Service Diagnostic mode. See TEST #5: Moisture Sensor,
Communication between the ACU and HMI has not been detected.
dz Unplug dryer or disconnect power.
dz Check the harness continuity and connections between the ACU and HMI.
dz Check AC and DC supplies.
dz Replace the HMI.
dz Replace the ACU.
Indicates the motor circuit is open or shorted.
page
20.
Indicates the heat system is open or shorted. F1E1 fault for heat system will only
appear when in Service Diagnostic mode.
page
21.
page
24.
F (-8
C) (> 50 kΩ), the exhaust thermistor is open. If the temperature
°
°
F (121
C) (< 500 Ω), the exhaust thermistor has shorted. May occur if
°
°
Test #1: ACU Power
page
22.
page
23.
Check, page 18.
15