Installation Instruction; Installation Height - IME VS133-868M User Manual

Ai tof people counting sensor
Table of Contents

Advertisement

Parameters
Adjust the ToF frequency modulation mode to avoid the interference of
surrounding IR devices. Please avoid using the same mode if there are multiple
Frequency
VS133 devices around.
Adjustment
Note:
if there is only one option, please contact Milesight IoT support:
iot.support@milesight.com
Recovery device basic configuration: keep the IP settings and user information
when resetting.
Reset
Recovery device to factory settings: reset device to factory default, which
needs to verify admin password.
Reboot
Restart the device immediately.
Click the folder icon and select the upgrading file, then click the Upgrade button
to upgrade. The update is done when the system reboots successfully.
Upgrade
Note:
The upgrade process takes about 1-10 minutes. Do not turn off the power
and complete automatic restart after the upgrade.
Export Config File: Export configuration file.
Backup and
Import Config File: Click the file icon and select the configuration file, click
Restore
Import button to import configuration file.

6. Installation Instruction

Parameter definition:
Parameters
H
d
Δd
h
max
h
min
α
β
x
y

6.1 Installation Height

The maximum installation height is 3.5 m and the minimum installation height is h
Description
Explanation
Installation height
Minimum detection distance of VS133
Distance measurement error of VS133
Maximum pedestrian height
Minimum pedestrian height
ToF horizontal field of view angle
ToF vertical field of view angle
Length of detection range
Width of detection range
Value
≤3.5 m
0.5 m
0.035 m
Example 1.8 m
Example 1.7 m
98°
80°
+d+Δd. For
max
24