  • Page 1 Environment Monitoring Sensor Featuring LoRaWAN ® EM300 Series User Guide...
  • Page 2 Applicability This guide is applicable to EM300 series sensors shown as follows, except where otherwise indicated. Model Description EM300-TH Temperature and Humidity Sensor EM300-MCS Magnet Switch Sensor EM300-SLD Spot Leak Detection Sensor EM300-ZLD Zone Leak Detection Sensor EM300-DI Pulse Counter Sensor...
  • Page 3 For assistance, please contact Milesight technical support: Email: iot.support@milesight.com Support Portal: support.milesight-iot.com Tel: 86-592-5085280 Fax: 86-592-5023065 Address: Building C09, Software Park III, Xiamen 361024, China Revision History Date Doc Version Description Oct. 14, 2020 V 1.0 Initial version Oct. 21, 2020 V 1.1...
  • Page 4: Table Of Contents

    Contents 1. Product Introduction ......................... 5 1.1 Overview ...........................5 1.2 Features ........................... 5 2. Hardware Introduction ........................5 2.1 Packing List ..........................5 2.2 Hardware Overview ......................... 6 2.3 GPIO Wiring (EM300-DI) ......................6 2.3 Dimensions ..........................6 2.4 Power Button ........................... 7 3.
  • Page 5: Product Introduction

    1. Product Introduction 1.1 Overview EM300 series is a sensor mainly used for outdoor environment through wireless LoRaWAN ® network. EM300 device is battery powered and designed for multiple mounting ways. It is equipped with NFC (Near Field Communication) and can easily be configured by a smartphone.
  • Page 6: Hardware Overview

    2.2 Hardware Overview Front View: ① NFC Area Bottom View: ② Vent ③ Waterproof Connectors (For EM300-DI/MCS/SLD/ZLD) 2.3 GPIO Wiring (EM300-DI) 2.3 Dimensions(mm)
  • Page 7: Power Button

    2.4 Power Button Note: The LED indicator and power button are inside the device. Switch on/off and reset can also be configured via NFC. Function Action LED Indication Turn On Press and hold the button for more than 3 seconds.
  • Page 8: Lorawan Settings

    3) EM300 series can also be configured by dedicated NFC reader provided by Milesight IoT or you can configure it via TTL interface inside the device. 3.2 LoRaWAN Settings LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN ®...
  • Page 9 Parameters Description Device EUI Unique ID of the device which can also be found on the label. App EUI Default App EUI is 24E124C0002A0001. Application Port The port used for sending and receiving data, default port is 85. Join Type OTAA and ABP mode are available.
  • Page 10 Spread Factor If ADR is disabled, the device will send data via this spread factor. If the device does not receive ACK packet from network server, it will resend Confirmed Mode data once. The device will send a specific number of LinkCheckReq MAC packets to the Rejoin Mode network server every 30 mins to validate connectivity;...
  • Page 11: Time Synchronization

    All: Enabling all channels Null: Indicates that all channels are disabled 3.3 Time synchronization ToolBox App Sync: Go to Device -> Status of ToolBox App to click Sync to sync the time. Network Server Sync: Go to Device > Settings > LoRaWAN Settings of ToolBox App to change device LoRaWAN ®...
  • Page 12: Basic Settings & Interface Settings

    3.4 Basic Settings & Interface Settings Go to Device > Setting > General Settings to change the reporting interval, etc. Parameters Description Reporting interval of transmitting current sensor values to network Reporting Interval server. Default: 10 min Change the temperature unit displayed on the ToolBox.
  • Page 13: Advanced Settings

    3.5 Advanced Settings 3.5.1 Calibration Settings ToolBox supports temperature and humidity calibration. Go to Device > Setting > Calibration Settings to type the calibration value and save, the device will add the calibration value to raw value. 3.5.2 Threshold Settings Go to Device >...
  • Page 14 3.5.4 Data Storage EM300 series sensor supports storing more than 2000 data records locally and exports data via ToolBox App. The device will record the data according to reporting interval and even joining network. 1. Go to Device > Setting > General Settings to enable data storage feature.
  • Page 15 3. Click Data Cleaning to clear all stored data inside the device.
  • Page 16: Data Retransmission

    3.5.4 Data Retransmission EM300 series sensor supports data retransmission to ensure network server can get all data even if network is down for some times. There are two ways to get the lost data: Network server sends downlink commands to to enquire the historical data for specifying ...
  • Page 17: Milesight D2D Settings

    4. After the network connected back, the device will send the lost data from the point in time when the data was lost according to the reporting interval. Note: 1) If the device is rebooted or re-power when data retransmission is not completed, the device will re-send all retransmission data again after device is reconnected to the network;...
  • Page 18: Maintenance

    Note: 1) If you enable LoRa Uplink, a LoRaWAN ® uplink packet that contains the sensor status or temperature threshold alarm will be sent to gateway after the Milesight D2D control command packet. Otherwise, sensor status or threshold alarm will not send to LoRaWAN gateway.
  • Page 19: Backup

    3.6.2 Backup EM300 devices support configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRaWAN ® frequency band. 1. Go to Template page on the App and save current settings as a template. You can also edit the template file.
  • Page 20: Reset To Factory Default

    3.6.3 Reset to Factory Default Please select one of following methods to reset device: Via Hardware: Hold on power button (internal) for more than 10s until LED blinks. Via ToolBox App: Go to Device > Maintenance to click Reset, then attach smart phone with NFC area to device to complete reset.
  • Page 21: Device Payload

    2. Drill the holes according to the marks and screw the wall plugs into the wall. 3. Mount the EM300 to the wall via mounting screws. 4. Cover the mounting screws with screw caps. 5. For leak detection senor, install the probe/cable to the place where liquid may leak;...
  • Page 22: Basic Information

    For decoder examples please find files on https://github.com/Milesight-IoT/SensorDecoders. 5.1 Basic Information EM300 series sensors report basic information of sensor whenever joining the network. Channel Type Description 01(Protocol Version) 01=>V1 09 (Hardware Version) 01 40 => V1.4 0a(Software Version) 01 14 => V1.14...
  • Page 23: Downlink Commands

    Examples: EM300-SLD/ZLD: 01 75 64 03 67 10 01 04 68 71 05 00 01 Channel Type Value Channel Type Value 10 01 => 01 10 = 272 64 => 100% (Temperat Temp=272*0.1=27.2°C (Battery) ure) Channel Type Value Channel...
  • Page 24 011 - within 100 - below or above Bit3~Bit7: 11001 10 (Reboot) ff(Reserved) 4 Bytes, Number(1B)+Function(1B)+D2D Command(2B) Number: 01 -Temperature threshold trigger 02 -Temperature threshold doesn’t 79(Set D2D settings) trigger 03 - Status trigger 04 -Status doesn’t trigger Function:...
  • Page 25: Historical Data Enquiry

    CTRL:cc =>11001100 06 (Set Threshold 100 = below or above Alarm) Min:96 00=> 00 96 = 15°C Max: 2c 01=>01 2c = 30°C 4. Set D2D settings of temperature threshold trigger. ff 79 01011001 Channel Type Value Number: 01, temperature threshold trigger...