Ai tof people counting sensor
Table of Contents

Advertisement

Parameters
Set the device installation height. Click Detect to detect the current
installation height automatically.
Note:
Installation
1) Ensure that there are no objects directly below the device avoiding
Height
interfering the height detection.
2) The automatic detection of the installation height is not supported with
dark floor/carpet (black, grey, etc.)
Max. Target
Set the maximum target height, then the device will ignore the objects
Height
higher than this setting value.
Min. Target
Set the minimum target height, then the device will ignore the object
Height
shorter than this setting value.
Select the tracking mode of counting, including Heads Tracking and Feet
Tracking.
Tracking Mode
Note: It is recommended to use heads tracking mode when the installation
height is low in standalone working mode.
When enabled, it allows to draw an area for every line and the device will
count the In and Out values only when people pass this area. Users can
U-turns Filtering
left-click to start the drawing and add edges for this area, then right-click to
stop drawing.
Description