Step 3: The configuration is displayed in the list after the configuration is
complete. You can redraw the areas by clicking the redraw button in the
list. And click the edit button to modify the advanced settings of the areas
or click delete button to delete the areas separately.
Reset
Enable to periodically reset cumulative count on schedule.
Cumulative
Cumulative Count includes:
Count on
Total In/Out counting of each detection line.
Schedule
Max./Avg. Dwell Time of each detection region.
Periodic Report
Report the people counting data periodically.
Set the period of reporting periodic report.
Period
Range: 1-1080 mins, default: 10 mins
Note:
Due to the error in ToF distance measurement (0.035 m), the Max. Target Height should be set
as maximum pedestrian height plus 0.035 m and the Min. Target Height as minimal pedestrian
height minus 0.035 m in the actual applications. For example, if the pedestrian height is 1.6 m to
1.8 m, the Max. and Min. Target Height should be configured as 1.835 m and 1.565 m
respectively.
5.3 Communication
5.3.1 WLAN
VS133 supports wlan feature to work as AP mode to configure device and it can not connect to
other access point.
14