KIT CONTENTS ELECTRICAL CHARACTERISTICS OPERATION MANUAL MODE AUTOMATIC (Proximity) MODE VALET MODE Service Key Receptacle Installation WIRING DIRECTIONS and PRECAUTIONS WIRING DIAGRAM Check Service Key and ID-Tag Operation Finalising the Installation Replacement ID-Tag Programming TROUBLESHOOTING Dealer Support MSM43J(T)1702020...
Page 3
Operating Voltage M43J 12v Version 12V (9-15V) Operating Voltage M43J 24v Version 24V (18-30V) Current consumption (Ign. OFF) <3mA Relay Current Rating (Wires 7+8) Relay Configuration Normally Open Relay Current Rating (Wires 4+5) Relay Configuration Normally Open (in-built Fail-Safe circuitry)
Page 4
ARMING: Approx. 15 seconds after Ignition OFF the immobiliser will ARM and the LED will flash every 2 seconds. If the Ignition is switched ON without pressing the ID-Tag button the Immobiliser LED will become ON solid to indicate the immobiliser is still armed. DISARMING: Once inside the vehicle press the button of the ID-Tag and start the vehicle within 8 seconds;...
Page 5
(Non-Insurance Installations Only) To set the immobiliser into Valet mode insert the service key into the receptable momentarily; the LED will give one long flash to confirm. The immobiliser will now remain in a disarmed state until the service key is used again. Thereafter, the immobiliser will return to automatic arming mode.
Page 6
Connect to IGNITION (+15) via the supplied fuse and holder. ENSURE the ignition remains live whilst cranking Connect to Permanent POSITIVE (+30) via the supplied fuse and holder. Connect to GROUND (-31) Connect to a different GROUND (-31) point See Diagram on next page Connect to RED/BLACK of LED Connect to BLACK of LED RELAY 1...
Page 8
1. With the ignition OFF and the immobiliser armed, insert the Service Key into receptable momentarily; the LED will give one long flash. 2. Press the button of the first ID-Tag and check the immobiliser LED flashes once. 3. Repeat for the second ID-Tag. 4.
Page 9
NOTE: When adding a new ID-Tag all existing ID-Tags must also been reprogrammed. Preparing the ID-Tags for programming: New ID-Tags: Ensure the ID-Tags are not flashing; if they are then follow the instructions for ‘Existing ID-Tags’. Existing ID-Tags: Remove the ID-Tag battery for 5 seconds then re-insert. Programming ID-Tags 1.
Page 10
The Immobiliser clicks when trying the start the vehicle: a. Ensure the wires ‘KEY’ and ‘3A’ have been inserted into the 2-way connector supplied. b. Ensure the ignition connection is not on the dead side of the cut i.e. it must remain live when the cut is open.
Need help?
Do you have a question about the M43J and is the answer not in the manual?