Left even
2-10 ABM bay grounding schemes

ABM bay frame ground

The ground wire used for the ABM bay frame ground must be a 6 AWG
conductor with green colored insulation, connectorized at one end with a
crimp-type two-hole lug as shown in Figure 2-5. The ABM bay frame ground
attaches to the top of the ABM bay as shown in Figure 2-6.
Figure 2-5
Frame ground lug connection
Figure 2-6
Connecting the frame ground
To frame ground
collector or
single point
building ground
Metallic
ground strip
AccessNode P0887749 Issue 1.0