Nortel SONET AccessNode Quick Reference Manual page 36

Abm bay cable connection
Hide thumbs Also See for SONET AccessNode:
Table of Contents

Advertisement

Left even
4-6 ABM bay connections
Table 4-2 (continued)
ABM bay external connections
Connection/Cable
From
Orderwire extension /
Orderwire Extension
NT4K85CA-CF
(J04) connector on the
ABM shelf SIL
BIP wire-wrap external
BIP wire-wrap block
connections /
Note: See Figure 4-3 on
Customer-provided
page 4-9 for the pin-out
wire-wrap cable
details of the BIP
consisting of twisted 22,
wire-wrap block.
24, or 26 AWG solid wire
cables. Maximum of 42
conductors.
Test access path (TAP) /
TAP input/output (I/O)
NT4K85EA-ED
card in slot 53 of the
ABM shelf I/O section
Pair gain test control
PGTC/MTA I/O card in
(PGTC) and metallic test
slot 52 of the ABM shelf
access (MTA) /
I/O section
NT4K85BA
Test bypass pair (TBP) /
TBP I/O card in slot 51 of
NT4K85EA-ED
the ABM shelf I/O
section
VT 100 terminal or
I/O card in slot 40 of the
remote printer /
ABM shelf I/O section
NT7E44VA/VB
Graphic terminal or
I/O card in slot 38 of the
remote operating
ABM shelf I/O section
system / NT7E44TA/TB
AccessNode P0887749 Issue 1.0
To
Orderwire office equipment.
Customer-selected external
equipment for alarms, parallel
telemetry, and orderwire
Distribution frame
External PGTC/MTA equipment or
next bay
Master distribution frame
VT 100 terminal or remote printer
Graphic terminal or remote
operating system
—continued—