Hoymiles HYT-5.0HV-AUG1 User Manual

Hoymiles HYT-5.0HV-AUG1 User Manual

Hide thumbs Also See for HYT-5.0HV-AUG1:

Advertisement

Quick Links

Region: Australia REV1.0
USER MANUAL
Open Energy for All
HYT-5.0HV-AUG1
HYT-6.0HV-AUG1
HYT-8.0HV-AUG1
HYT-10.0HV-AUG1
HYT-12.0HV-AUG1
HAT-5.0HV-EUG1
HAT-6.0HV-EUG1
HAT-8.0HV-EUG1
HAT-10.0HV-EUG1
HAT-12.0HV-EUG1
hoymiles.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYT-5.0HV-AUG1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hoymiles HYT-5.0HV-AUG1

  • Page 1 Open Energy for All USER MANUAL HYT-5.0HV-AUG1 HYT-6.0HV-AUG1 HYT-8.0HV-AUG1 HYT-10.0HV-AUG1 HYT-12.0HV-AUG1 HAT-5.0HV-EUG1 HAT-6.0HV-EUG1 HAT-8.0HV-EUG1 HAT-10.0HV-EUG1 HAT-12.0HV-EUG1 Region: Australia REV1.0 hoymiles.com...
  • Page 2: Table Of Contents

    3.4.5.5 DO Connection 3.4.5.6 Parallel Connection 3.4.6 DTS Connection 3.5 Operation 3.5.1 Commissioning 3.5.2 Decommissioning 3.5.3 S-Miles Cloud App 3.5.3.1 DTS Online Setting 3.5.3.2 System Commissioning of Wireless Access Point (AP) Connection © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 3 3.5.3.5 Earth Fault Alarm 3.5.3.6 Export Limit Settings 3.5.3.7 Firmware Version 3.5.4 Routine Maintenance 4. Troubleshooting 5. Technical Datasheet 5.1 HYT Series Technical Parameters 5.2 HAT Series Technical Parameters Appendix A Appendix B © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 4: Safety Introduction

    After the inverter is turned off, wait for at least 10 minutes before opening the inverter or touching live parts. 10min Products shall not be disposed as household waste. CE mark. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 5: Safety Information

    Safety instructions in this manual cannot cover all precautions that should be taken. Please consider the actual conditions on site when performing operations. Any damage caused by a violation of the safety instructions in this manual shall not be the responsibility of Hoymiles. Symbol...
  • Page 6 The manual contains no instructions for user-serviceable parts. See Warranty for instructions on obtaining service. • If an error occurs, refer to troubleshooting or contact your local distributor or qualified electricians. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 7: Product Introduction

    PV Terminals* Battery Terminals Data Transfer Stick (DTS) Port Communication Port GRID Connector Generator (GEN) Connector LED Indicators Label Emergency Power Supply (EPS) Connector PE Terminal * Only for HYT-HV-AUG1 series. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 8 On – BMS and meter communications are normal Off – No fault On - A fault happens FAULT Blink 1 – EPS port overload Blink 2 – ISO/RCD fault Blink 3 – Arc fault © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 9: Operating Modes

    Meanwhile, the battery can be forced to charge from the grid Economic Mode during the preset charge time. For instance, the battery could be charged or discharged according to valley or peak electricity price. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 10 PV surplus power selling Discharge stopped when set SOC is Consuming from grid reached Loads Battery charging Self consuming (PV power generation) 24:00 00:00 standby charging standby discharging standby Power flow of back-up mode © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 11: System Diagram

    • Please refer to https://www.hoymiles.com for compatible battery list, and the user should first contact Hoymiles for technical consultation and obtain official confirmation prior to installing any battery not included in NOTICE the official published list. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 12: Basic Diagram

    If the battery integrates a readily accessible internal DC breaker, no additional ① DC breaker is required. • • ⑥⑦ 30 mA RCD is recommended but not mandatory; please comply with local regulation. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 13 If the battery integrates a readily accessible internal DC breaker, no additional ① DC breaker is required. • • ⑦⑧ 30 mA RCD is recommended but not mandatory; please comply with local regulation. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 14: Retrofit System

    The HYT/HAT-HV series inverter is compatible with any three-phase grid-connected PV inverters. With the addition of Hoymiles hybrid inverter or AC-coupled inverter, existing PV system can be retrofitted to be a PV Energy Storage Syestem (ESS) allowing more self-consumption energy and more backup energy.
  • Page 15: Unacceptable Diagram

    Neither EPS or on-grid port can be connected to generator Single PV cannot be connected to multiple inverters. directly. Incompatible battery EPS port cannot be connected to grid directly. Incompatible battery cannot be connected to battery port. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 16: Installation Instruction

    Hybrid Inverter User Manual 3. Installation Instruction 3.1 Packing List Please ensure that none of the components listed below are missing or damaged upon receipt of the hybrid inverter or AC-coupled inverter. HYT Series © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 17: Installation Tools

    Wire stripper Hydraulic pliers Network cable crimper PV terminal Tubular termianl OT terminal Heavy-duty connector Protective goggles crimping tool crimping tool crimping tool crimping tool Safety gloves Dust mask Safety shoes © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 18: Mounting

    7. The inverter should be installed at eye level for convenient maintenance. 8. The product label on the inverter should be clearly visible after installation. 9. The inverter should be installed far from flammable materials. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 19: Mounting Inverter

    Prepare the cable and OT/DT Step 1 terminal. L=H+(2-3) mm Use the screw from the S 4 mm² Step 2 accessory box. Then fasten the cable with a screwdriver. 1.2 N·m © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 20: Ac Wiring Connection

    Assemble the parts in sequence. • Tighten the waterproof terminal clockwise. • Connect the grid connector to the inverter. Step 5 There should be a “click” sound, if it is plugged in correctly. Click © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 21: Gen Connection (For Hat Series Inverters)

    Never connect a load between the inverter and the circuit breaker. • Make sure the EPS load power rating is within the EPS output rating, otherwise the inverter will shut down with an “overload” warning. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 22 Make sure the L/N/PE are correctly assembled. • Assemble the parts in sequence. • Tighten the waterproof terminal clockwise. Step 5 • Connect the EPS connector to the inverter and tighten it. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 23: Pv Wiring Connection (For Hyt Series Inverters)

    Step 4 inverter input limit of 1,000 V. • Connect the PV connectors to the inverter. There should be a “click” sound if they are Click plugged in correctly. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 24: Battery Wiring Connection

    600 V. • Connect the battery connectors to the Step 4 inverter. There should be a “click” sound if they are plugged in correctly. Click © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 25: Communication Wiring Connection

    Dry contact output. The DO1 can be set to one of the DO1 (NO1, COM1) functions as follows: Earth Fault Alarm, Load Control and Generator Control. Dry contact output. The DO2 will control the bypass DO2 (NO2, COM2) contactor under certain logic. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 26: Bms Connection

    • Clip the ethernet cable into the rubber ring. • Insert the RJ45 plug into the BMS port until it Step 5 clicks into place. • Tighten the cable gland. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 27: Smart Meter And Ct Connection

    Clamp three CTs to L1/L2/L3 and connect wirings to 13/14, 16/17, and 19/21 respectively. The arrow on the surface of CT should point to the grid. Step 1 • Connect the communication cable between the inverter and smart meter. Step 2 485B 485A © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 28: Drm Connection

    Disassemble the parts in sequence. • Strip the insulation layer of the communication cable, and lead the Step 3 corresponding signal cables out. Press the terminal. A: 35-45 mm B: 7-8 mm C: 0.2-0.35 mm² © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 29: Di Connection

    There is an integrated DI (IN+, IN-) as the dry contact input to the bypass contactor of the inverter. The connection method is the same as that described in “3.4.5.3 DRM Connection”. Wiring the No.1 and No.2 holes if used, and the function of each connection position is shown below. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 30: Do Connection

    “3.5.3.5 Earth Fault Alarm“. The DO2 can control the external bypass contactor if used, and for more information, please contact Hoymiles technical support team. The connection method is the same as that described in “3.4.5.3 DRM Connection”.
  • Page 31: Dts Connection

    Proper communication with the inverter. Improper communication with the inverter. Proper communication with S-Miles Cloud. Improper communication with S-Miles Cloud BLINK Improper communication with S-Miles Cloud, but the network is connected. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 32: Operation

    Warning signs and labels are intact. • After the commissioning of the inveter, country grid code,firmware version and region settings (and setpoints) for grid protection settings and power quality response modes can be viewed through Hoymiles App referring to “3.5.3 S-Miles Cloud App” and “Appendix B”.
  • Page 33: S-Miles Cloud App

    S-Miles End-user 3.5.3.1 DTS Online Setting 1. Search “Hoymiles” in the App Store (iOS) or the Play Store (Android), or scan the QR code to download the Hoymiles Installer App. 2. Open the app and log in with your installer account and password. For new Hoymiles installers, please apply for an installer account from your distributor in advance.
  • Page 34 5. Check the DTS indicator for a solid blue light, which signifies a successful connection. The network configuration takes about 1 minute, please be patient. If the network is not connected, please check the internet as instructed. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 35: System Commissioning Of Wireless Access Point (Ap) Connection

    The password can not be readily available, and it is available from Hoymiles upon request. We classify the installer account and user account through authority management, and the end-user has no authority to set grid standard code.
  • Page 36 Hybrid Inverter User Manual © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 37 GEN port is “PV Generator” or “Diesel Generator”, and click “Save”. (The default option is “None”.) 6. Make sure that all cables including DC cables, AC cables and communication cables are properly connected, and all DC and AC switches are turned on, and then click “Self-check”. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 38: Drm Setting

    Click the plant that you want to view, click the rhombus icon at the bottom right corner, and then click “Dry Contact Configuration → Earth Fault Alarm“ button to enable this function. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 39: Export Limit Settings

    “Appendix B”. And the meter provided by Hoymiles should be installed on the grid side if you want to use this function. 3.5.3.7 Firmware Version Click the plant that you want to view, click the rhombus icon at the bottom right corner, and click “Device List →...
  • Page 40: Routine Maintenance

    The first check is 3 months after the first installation, and the Check whether the ground wires are firmly Grounding Reliability subsequent inspections can be connected. carried out once every 6 to 12 months. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 41: Troubleshooting

    1. Check the specification and numbers of corresponding The PV voltage is higher than string PV modules. PV Overvoltage the permissible range. 2. If the alarm persists, contact Hoymiles technical support team. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 42 BMS Communication The inverter detects that there 2. Reconnect the BMS communication cable. Fault is a BMS communication fault. 3. If the alarm persists, contact Hoymiles technical support team. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 43 BMS. battery manufacturer. The inverter detects that there Try to restart the inverter. If the fault persists, contact Relay Fault is a relay self-check fault. Hoymiles technical support team. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 44: Technical Datasheet

    EN 50549, VDE-AR-N 4105, AS/NZS 4777.2 Safety Regulation IEC 62109-1, IEC 62109-2 EN 61000-6-1, EN 61000-6-3 (1) AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with Positive Feedback. © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 45: Hat Series Technical Parameters

    Isolation Method (Battery) Transformerless Country of Manufacture China Certifications and Standards Grid Regulation EN 50549, VDE-AR-N 4105, AS/NZS 4777.2 Safety Regulation IEC 62109-1, IEC 62109-2, IEC 62477-1 EN 61000-6-1, EN 61000-6-3 © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 46 AUSTRALIA-AS4777_ New Zealand Supported Supported Supported Supported Supported A_HV_NZ_400 power grid Spain HV power RD1699/166 Supported Supported Supported Supported Supported grid Poland power EN50549-poland Supported Supported Supported Supported Supported grid © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 47 Emirates power Supported Supported Supported Supported Supported grid TNB+IEC60068 Supported Supported Supported Supported Supported AS 4777.2 Israel power grid Supported Supported Supported Supported Supported Mexico power Supported Supported Supported Supported Supported grid © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 48 AUSTRA- New Zealand LIA-AS4777_NZ_ Supported Supported Supported Supported Supported power grid HV400 Spain HV power RD1699/166 Supported Supported Supported Supported Supported grid Poland power EN50549-poland Supported Supported Supported Supported Supported grid © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 49 Emirates power Supported Supported Supported Supported Supported grid TNB+IEC60068 Supported Supported Supported Supported Supported AS 4777.2 Israel power grid Supported Supported Supported Supported Supported Mexico power Supported Supported Supported Supported Supported grid © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 50 500 mA 200 mA-1000 mA Maximum Trip Time (MTT) 150 ms 150 ms 150 ms 100 ms-1000 ms DC Injection Current LV1 200 mA 200 mA 200 mA 200 mA-1000 mA © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 51 Reactive Set Point Q1 44.00% 30.00% 44.00% 30%-60% Reactive Set Point Q2 0.00% 0.00% 0.00% 0-0% Reactive Set Point Q3 0.00% 0.00% 0.00% 0-0% Reactive Set Point Q4 60.00% 40.00% 60.00% 30%-60% © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 52 0-200% Maximum Trip Time (MTT) 15s-20s Generation Soft Limit Ratio 100% 100% 100% 0-200% Generation Hard Limit Ratio 110% 110% 110% 0-200% Maximum Trip Time (MTT) 15s-20s Reconnection Time (RT) 1s-100s © 2023 Hoymiles Power Electronics Inc. All rights reserved.
  • Page 53 S-Miles Installer S-Miles End-user Floor 6-10, Building 5, 99 Housheng Road, Gongshu District, Hangzhou 310015 P. R. China +86 571 2805 6101 General inquiry: info@hoymiles.com Technical support: service@hoymiles.com Visit https://www.hoymiles.com/ for more information.

Table of Contents