Open Energy for All Hybrid/AC-coupled Inverter USER MANUAL HYS-3.0LV-EUG1 HYS-3.6LV-EUG1 HYS-4.6LV-EUG1 HYS-5.0LV-EUG1 HYS-6.0LV-EUG1 HAS-3.0LV-EUG1 HAS-3.6LV-EUG1 HAS-4.6LV-EUG1 HAS-5.0LV-EUG1 Region: Global REV2.2 hoymiles.com...
Safety instructions in this manual cannot cover all precautions that should be taken. Please consider the actual conditions on site when performing operations. Any damage caused by a violation of the safety instructions in this manual shall not be the responsibility of Hoymiles. Symbol...
If an error occurs, contact your local distributor or qualified electricians. 1.3 EU Declaration of Conformity Hoymiles Power Electronics Inc. hereby declares that the inverter described in this document is in compliance with the basic requirements and other relevant provisions of the following directives.
• Please refer to https://www.hoymiles.com for the compatible battery list, and the user should first contact Hoymiles for technical consultation and obtain official confirmation before installing any battery not included in the official published list. • Lead-acid battery is not recommended for general customers as it requires...
The HYS-LV series inverter is compatible with any single-phase grid-connected PV inverter. With the addition of the Hoymiles hybrid inverter, the existing PV system can be retrofitted to be a PV Energy Storage System (ESS) allowing more self-consumption energy and more backup energy.
• If the PV inverter is connected to the GEN port or EPS port, the power of the PV inverter shall be less than the rated output power of Hoymiles hybrid inverter. • If power export management is required, the power of the PV inverter shall be less than the battery charge power.
The HAS-LV series inverter is compatible with any single-phase grid-connected PV inverter. With the addition of the Hoymiles AC-coupled inverter, the existing PV system can be retrofitted to be a PV Energy Storage System (ESS) allowing more self-consumption energy and more backup energy.
• If the PV inverter is connected to the GEN port or EPS port, the power of the PV inverter shall be less than the rated output power of Hoymiles AC-coupled inverter. • If power export management is required, the power of the PV inverter shall be less than the battery charge power.
NOTICE There is one smart meter in our packing box, and the other needs to be purchased from Hoymiles. The meter address is automatically set. If there are meter communication problems, please check if the address of the PV side meter is set to 1, and the address of the grid side meter is set to 2.
EPS side. If the PV inverter is connected to the EPS side, the power of the PV inverter shall be less than the total output of Hoymiles energy storage inverter. If power export management is required, the power of the PV inverter shall be less than the battery charge power. The zero-export function will be disabled after the battery is fully charged.
System Power-off Procedure Step 1 Stop the inverter from working via the Hoymiles App. Step 2 Disconnect the AC breaker between the inverter and the grid. (Only for HYS series inverters) Rotate the DC switch to “OFF” if the inverter is connected to Step 3 the PV strings.
S-Miles End-user 3.5.3.1 DTS Online Setting 1. Search “Hoymiles” in the App Store (iOS) or the Play Store (Android), or scan the QR code to download the Hoymiles Installer App. 2. Open the app and log in with your installer account and password. For new Hoymiles installers, please apply for an installer account from your distributor in advance.