MC250
WARNING:
Make sure that the cable is aligned with the holder and rolls up perfectly. Check that
there is no interference of the cable with cable guides or with the moving parts of
the hoist.
2.5.11 Access protection
2.5.11.1 Ground level protection
WARNING:
It is mandatory to protect the ground access level for load, with vertical protection
of h = 1,1 ÷ 1,2 m (43.30 ÷ 47.24 in), and also intermediate rail with no more than 0,5
m (19.68 in) vertical distance.
2.5.11.2 Vertical travel protection
Access of persons to vertical hoist travel shall be protected, to prevent accidents when there is
risk of a fall from height more than 2 m (6 ft 6.74 in).
If openings in the vertical travel protection are necessary to access the load, they should not
exceed necessary width to allow the opening of the cage door.
2.5.11.3 Loading and unloading areas
In cases in which you can´t designate default loading or unloading areas, where the hoist should
WARNING:
The hoist shall be operated from a point from wich you have full visibility of
(+34) 944 71 16 00 (+34) 944 53 17 54 export@alba.es
MC250 Rev.02-USA
complete travel.