Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Keithley Manuals
Measuring Instruments
610B
Instruction manual
Keithley 610B Instruction Manual page 37
Multi-range electrometers
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
page
of
63
Go
/
63
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
MODELS 610B,
610BR ELECTROMETERS
MAINTENANCE
Control
Circuit
Designation
Ohms Calibration
Rll5
18
4-10
Meter
Center
Zero
Calibration
R167
18
4-11
Meter
Calibration
R175
18
4-11
DC Amplifier
Balance
RL77
19
4-8
TABLE 4.
Model
610B Internal
Controls.
The Table
Lists
all
internal
controls,
the
figure
picturing
the
location
and the paragraph
describing
the adjustment.
2.
The dc amplifier
balance
adjustment
(paragraph
4-8)
is necessary
about
every
six
months
or when amplifier
components
are replaced.
3.
Verify
the value
of the high-megohm
resistors
(paragraph
4-9)
about
every
six
months
to check
on drifting.
4.
Calibrate
the ohms ranges
(paragraph
4-10)
about
once a year
or when
range
resistor
or power
supply
components
are
replaced.
5.
Calibrate
the meter
zero
(paragraph
4-11)
about
once a year
or when
components
are
replaced.
6.
Check the Model
610B (paragraph
4-12)
once a year,
after
the
other
adjustments,
or if
improper
operation
is
suspected.
c.
If
the tide1
610B is not
within
specifications
after
the calibrations
and adjustments,
follow
the
troubleshooting
procedures
or contact
Keithley
Instruments,
Inc.,
or its
nearest
representative.
4-7.
GRID CURRENT
CHECK.
Check grid
current
whenever
excessive
noise
or drift
is
suspected.
To read
the grid
current
of
the Model
610B,
set
the
front
panel
controls
to:
METER Switch
+
tiltiplier
Switch
.Ol
Range Switch
10-11
AMPERES
ZERO CHECK Button
Unlocked
FEEDBACK Switch
FAST
Cap the INPUT Rece
less
than
2 x 10-L e
tacle.
The grid
current
indicated
on the meter
should
be
ampere.
If
this
is
exceeded,
check
the
+Zl volt
supply
and the electrometer
Tube,
VlOl.
4-8.
DC AMPLIFIER
BALANCE ADJUSTMENT.
Gradual
aging
of components
may require
an occasional
adjustment
of the amplifier
balance.
Also
adjust
if
amplifier
components
are
replaced.
This
adjustment
sets
the
gain
to allow
the meter
to
receive
the
correct
signal
on all
ranges.
1064R
33
Table of
Contents
Previous
Page
Next
Page
1
...
34
35
36
37
38
39
40
41
Advertisement
Table of Contents
Related Manuals for Keithley 610B
Measuring Instruments Keithley 610 Manual
Electrometer (32 pages)
Measuring Instruments Keithley 610C Instruction Manual
Solid-state electrometers (47 pages)
Measuring Instruments Keithley 610C Instruction Manual
(44 pages)
Measuring Instruments Keithley 617 Instruction Manual
Programmable electrometer (183 pages)
Measuring Instruments Keithley 617 Quick Reference Manual
Programmable electrometer (55 pages)
Measuring Instruments Keithley 615 Instruction Manual
Digital electrometer (81 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (22 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (81 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (79 pages)
Measuring Instruments Keithley 6517B User Manual
Electrometer (90 pages)
Measuring Instruments Keithley 6430 Quick Results Manual
Sub-femtoamp remote sourcemeter (49 pages)
Measuring Instruments Keithley 6485 Instruction Manual
Picoammeter (312 pages)
Measuring Instruments Keithley 6487 Reference Manual
Picoammeter/voltage source (338 pages)
Measuring Instruments Keithley 6220 Reference Manual
Ac and dc current source measure unit (454 pages)
Measuring Instruments Keithley 600A Instruction Manual
Electrometer (31 pages)
Measuring Instruments Keithley 1793 Instruction Manual
Ieee standard 488 output (25 pages)
Related Products for Keithley 610B
Keithley 610
Keithley 610C
Keithley 610CR
Keithley 617
Keithley 615
Keithley 616
Keithley 6517B
Keithley 6430
Keithley 6485
Keithley 600B
Keithley 630
Keithley 620
Keithley 6482
Keithley 6512
Keithley 6482 E
Keithley 602
This manual is also suitable for:
610br
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL