Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Keithley Manuals
Measuring Instruments
610B
Instruction manual
Measurements - Keithley 610B Instruction Manual
Multi-range electrometers
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
page
of
63
Go
/
63
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
CIRCUIT
DESCRIPTION
MODELS 610B,
6LOBR ELECTROMETERS
.I101
?
L
Amplifier
+250 v z
Rs
(
.
I
FAST
-265 v C
Floating
Gnd
I
FIGURE 15.
Block
Diagram
of Model
610B as a Picoanuneter.
Circuit
designations
refer
to schematic
diagram.
SlO6 is
the tiltiplier
Switch;
I&, is
the
resistor
for
a given
setting.
Rs is
the
resistor
selected
by the Range Switch,
SlOl.
5102 is
the FEEDBACK Switch.
Ground
references
correspond
to schematic.
3-4.
AMMEIER OPERATION.
a.
Normal
Methc.4.
In the normal
method
of current
measurements
(FEEDBACK
Switch
in NORMAL position),
one of
the
Range Switch
resistors,
R102 through
Rl12,
shunts
the
input.
(See Figure
15.)
The Modal
6lOB than
measures
the
voltage
drop
acros8
the
resistor.
The meter
is
calibrated
to read
the
current
in amperes
for
the
appropriate
range.
b.
East
Method.
In the
fast
method
0f current
measurements
(FEEDBACK Stitch
in FAST position),
the
Model
610B functions
as an
anmeter
with
negative
feedback.
The differential
amplifier
output
is
divided
by the tiltiplier
Switch
resistors,
R156 to R166,
and fed back
to the amplifier
input
through
a feedback
resistor
selected'with
the Range Switch.
(See Figure
15.)
Floating
ground
is
connected
to the
low impedance
side
of the
input,
and the
output
ground
is
floating.
This
method
increases
the
response
speed by minimizing
the
effects
of input
capacity;
it
also
reduces
the
input
drop
to less
than
1 millivolt.
3-5.
OHhMEX'ER OPERATION.
a.
NoMl
Method
In the normal
method
of resistance
measurements
(FEEDBACK
Switch
in NORMALposition),
the Model
610B uses
a constant-current,
voltage-drop
circuit.
Refer
to Figure
16.
&
is
the unknown
resistor.
A voltage
source,
E,
applies
a potential
acros8
&.
The source
is
obtained
from
the
+21 volt
supply
through
the
resistor
divider
network,
Rll4
through
Rll8.
E varies
from 0.1
to
10 volts,
depending
upon
the
OHMS range
used.
The voltage
source
is
connected
between
floating
ground
and the
input
grid
of V103 through
R,,
the
range
re-
sistor.
Rs is
one of the
resistors,
R102 through
R112.
Since
feedback
to the
24
1064R
Table of
Contents
Previous
Page
Next
Page
1
...
25
26
27
28
29
30
31
32
Advertisement
Table of Contents
Related Manuals for Keithley 610B
Measuring Instruments Keithley 610 Manual
Electrometer (32 pages)
Measuring Instruments Keithley 610C Instruction Manual
Solid-state electrometers (47 pages)
Measuring Instruments Keithley 610C Instruction Manual
(44 pages)
Measuring Instruments Keithley 617 Instruction Manual
Programmable electrometer (183 pages)
Measuring Instruments Keithley 617 Quick Reference Manual
Programmable electrometer (55 pages)
Measuring Instruments Keithley 615 Instruction Manual
Digital electrometer (81 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (81 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (79 pages)
Measuring Instruments Keithley 616 Instruction Manual
Digital electrometer (22 pages)
Measuring Instruments Keithley 6517B User Manual
Electrometer (90 pages)
Measuring Instruments Keithley 6430 Quick Results Manual
Sub-femtoamp remote sourcemeter (49 pages)
Measuring Instruments Keithley 6485 Instruction Manual
Picoammeter (312 pages)
Measuring Instruments Keithley 6487 Reference Manual
Picoammeter/voltage source (338 pages)
Measuring Instruments Keithley 6220 Reference Manual
Ac and dc current source measure unit (454 pages)
Measuring Instruments Keithley 600A Instruction Manual
Electrometer (31 pages)
Measuring Instruments Keithley 1793 Instruction Manual
Ieee standard 488 output (25 pages)
Related Content for Keithley 610B
486 Current Measurements
Keithley 486
177 Trms Measurements {Ac + Dc)
Keithley 177
193 Dc Voltage Measurements
Keithley 193
415 Making Measurements
Keithley 415
602 Voltage Measurements
Keithley 602
193A Dc Voltage Measurements
Keithley 193A
6487 Measurements And Sourcing Voltage
Keithley 6487
610C Galvanometric Measurements
Keithley 610C
7077 Four-Terminal Ohms Measurements
Keithley 7077
6512 Making Voltage Measurements
Keithley 6512
6482 Low Current Measurements
Keithley 6482
2651A Contact Check Measurements
Keithley 2651A
196 Basic Measurements
Keithley 196
2450 Viewing The Measurements On The Front-Panel Graph
Keithley 2450
SourceMeter 2400 Series Figure 6 Guarded Ohms Measurements
Keithley SourceMeter 2400 Series
2601A How Do I Make Measurements
Keithley 2601A
This manual is also suitable for:
610br
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL