Troubleshooting - Graco Husky 232502 Instructions-Parts List Manual

Air-operated diaphragm pumps
Table of Contents

Advertisement

WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 9.
PROBLEM
Pump cycles at stall or fails to hold
pressure at stall.
Pump will not cycle, or cycles once
and stops.
Pump operates erratically.
Air bubbles in fluid.
12
308441

Troubleshooting

D Relieve the pressure before checking or servicing
D Check all possible problems and causes before
CAUSE
Worn check valve balls (301), seats
(201) or o-rings (202).
Air valve is stuck or dirty.
Check valve ball (301) severely
worn and wedged in seat (201) or
manifold (102 or 103).
Check valve ball (301) is wedged
into seat (201), due to overpressur-
ization.
Dispensing valve clogged.
Clogged suction line.
Sticky or leaking balls (301).
Diaphragm ruptured.
Restricted exhaust.
Suction line is loose.
Diaphragm ruptured.
Loose inlet manifold (102), dam-
aged seal between manifold and
seat (201), damaged o-rings (202).
Loose diaphragm shaft bolt (107).
Damaged o-ring (108).
the equipment.
disassembling the pump.
SOLUTION
Replace. See page 16.
Disassemble and clean air valve.
See pages 14–15. Use filtered air.
Replace ball and seat. See page
16.
Install Pressure Relief Valve
(see page 7).
Relieve pressure and clear valve.
Inspect; clear.
Clean or replace. See page 16.
Replace. See pages 17–19.
Remove restriction.
Tighten.
Replace. See pages 17–19.
Tighten manifold bolts (106) or re-
place seats (201) or o-rings (202).
See page 16.
Tighten or replace. See pages
17–19.
Replace. See pages 17–19.