Advertisement

Lubrication
The air valve is designed to operate unlubricated,
however if lubrication is desired, every 500 hours of
operation (or monthly) remove the hose from the pump
air inlet and add two drops of machine oil to the air
inlet.
CAUTION
Do not over-lubricate the pump. Oil is exhausted
through the muffler, which could contaminate your
fluid supply or other equipment. Excessive lubrica-
tion can also cause the pump to malfunction.
10
308441

Maintenance

Flushing and Storage
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 9.
Flush the pump often enough to prevent the fluid you
are pumping from drying or freezing in the pump and
damaging it. Use a compatible solvent.
Always flush the pump and relieve the pressure before
storing it for any length of time.