Step 4. Operating The Controls - Kenmore 758.154120 Operator's Manual

Whole house humidifier
Hide thumbs Also See for 758.154120:
Table of Contents

Advertisement

Available languages

Available languages

Step 4. Operating the Controls
Where
you set your desired
humidity
levels
depends on your personal comfort level, outside
temperature and inside temperature. A starting set
point
of
30%
-
40%
ROOM
humidity
is
recommended but there may be conditions that
require a different setting.
When Outdoor
Temperature
is:
2°F
_18°C
10 ° F
-12 ° C
20 ° F*
-6 ° C *
Recommended
Indoor
Relative Humidity (RH) is:
25%
30%
35%
* and above
IMPORTANT:
Water damage may result if
condensation starts to form on windows or
walls. Humidity SET point should be
lowered until condensation no longer forms.
We recommend room humidity levels do not
exceed 50%.
To Operate the Controls
Digital
Display
Press the power button once to display the digital
readout*. Initially there is a slight delay while the
electronics calibrate.
Two
bars
(-
-)
flash
during
this
time.
Once calibration is complete a ROOM
humidity
reading between 25% - 95% will be displayed. A
flashing 20 display indicates that the room humidity
is less than 20%.
NOTE:
After desired settings are selected by the
user, they remain as long as the unit remains
plugged in and there is no power interruption. If the
unit is unplugged the original
default settings are
employed.
* Humidifierfan shouldoperateat initialstart up. If it
does not, refer to, "Fan not operating(digitaldisplay is
illuminated)"in the "TroubleShooting"sectionon page
13 of this manual.
Digital Display
Fan Speed
Humidity
Control
7