Step 4. Operating; Operating Controls - Kenmore 758.154120 Operator's Manual

Whole house humidifier 12 gallon output with digital readout
Hide thumbs Also See for 758.154120:
Table of Contents

Advertisement

Step 4.
Where
you set your desired
humidity
levels
depends
on your
personal
comfort
level,
outside
temperature
and inside
temperature.
A starting
set point of 30% -
40% ROOM
humidity
is recommended
but there
may be conditions
that require
a
different
setting.
Operating
the Controls
--
When
Outdoor
Temperature
is:
-10 ° F
-24 ° C
2°F
-18°C
10 ° F
-12 ° C
20 ° F"
-6 ° C '
Recommended
indoor
Relative
Humidity
(RH) is:
20%
25%
30%
35%
IMPORTANT:
Water
damage
may
result
if condensation
starts
to form
on windows
or walls.
Humidity
SET
point should
be lowered
until
condensation
no longer
forms.
We
recommend
room
humidity
levels do
not exceed
50%.
* and above
To Operate
the Controls
Digital
Display
Press
the power
button
_)
once to
display
the digital
readout*,
initially
there
is a slight
delay while
the electronics
calibrate.
Two bars (- -) flash during
this time.
Once calibration
is complete
a ROOM
humidity
reading
between
25% - 95% will
be displayed.
A flashing
20 display
indicates
that the room humidity
is less
than 20%.
NOTE:
The default
settings
at initial
startup
are WHISPER
fan speed
and
65% SET humidity.
After desired
settings
are selected
by the user, they remain
as
long as the unit remains
plugged
in and
there is no power
interruption.
If the unit
is unplugged
the original
default
settings
are employed.
* Humidifier fan should operate at initial start
up. If it does not, refer to, "Fan not operating
(digital display is illuminated)" in the "Trouble
Shooting" section on page 13 of this manual.
Function
Buttons
\
Power/Refill
/
\
Light
_ Digital
Display