2 | Safety
2.9 Emergency procedure
2.9.1 Overheating of the system
2.9.2 Smell of flue gas
16
WARNING
If you open the combustion chamber door/fuel loading door during operation:
This could result in injury, damage or flue gas generation!
Therefore:
r Never open the combustion chamber door during operation
r The fuel loading door must be kept closed during operation and may only be opened
briefly during reloading intervals
If the system overheats and the safety devices fail to operate, proceed as follows:
NOTICE! Do not under any circumstances switch off the main switch or disconnect
the power supply.
r Keep all the doors on the boiler closed
r Open all mixing valve taps, switch on all pumps.
Ä The Froling heating circuit control takes on this function in automatic operation.
r Leave the boiler room and close the door
r Open any thermostatic valves on the radiator and ensure sufficient heat dissipation
from the rooms
If the temperature does not drop:
r Contact the installer or Froling customer services
DANGER
If you smell flue gas in the boiler room:
Inhaling toxic flue gas can potentially be fatal!
If you smell flue gas in the room where the boiler is installed:
r Keep all the doors on the boiler closed
r Ventilate the room where the boiler is installed
r Close the fire door and doors to living areas
r Allow the fire to burn out completely and let the boiler cool
Recommendation: Do not install smoke alarms and carbon monoxide detectors near the
system.
B1500423_en | Operating instructions Dual fuel boiler SP Dual compact
Need help?
Do you have a question about the SP Dual compact and is the answer not in the manual?