4.2 Notes on filling the fuel stores

When working in the fuel
store:
B1500423_en | Operating instructions Dual fuel boiler SP Dual compact
CAUTION
Filling the store when the boiler is switched on
could result in damage and consequential injury!
When filling the fuel store:
r Switch off the boiler by tapping "Boiler OFF"
Ä The boiler follows the shutdown procedure and switches to "Off" status
r Allow the boiler to cool for at least half an hour
When the boiler has cooled down:
r Before filling check the store for fines and clean if necessary
r Close all openings to the store to seal out dust
r Fill the store with pellets
Ä Only use permitted pellets!
Ü "Permitted uses" [} 9]
Risk of injury due to moveable parts!
Shut off the feeder unit before entering the fuel store!
When cleaning the fuel store, an increased amount of dust may be
generated. Wear a dust mask when working in the fuel store.
Adequately ventilate the fuel store before entering. Keep the door open
and always have a second person present. Observe the CO
concentration limit (< 30ppm).
Slick surfaces in the fuel store present a slipping hazard!
Unauthorized access prohibited! Keep children away!
Keep the fuel store locked and store the key in a safe place!
No fire, open flames or smoking in the fuel store!