After the module groups have a sequence selected, a flash pattern rate can be chosen. The default rates are as follows in TABLE 9.
To change a light head group flash pattern rate selection:
1. Power-up the Lightbar and apply +power to the appropriate level mode wires (see Table 3) and the BLK/RED Pattern select wire in the
16 conductor cable.
2. Momentarily touch the appropriate light head group wire, shown in Table 10, to +power to cycle through the flash pattern rates shown in
shown in Table 11.
Light Head Group Flash Rate Wires -
Function Wire Color
BLK
BLU/WHT
To restore the Factory Default Emergency Warning Flash Rate to module group in a level mode, hold the appropriate rate selection wire
and the BLK/RED wire to +power for more than four seconds. The four corner light heads will flash once, and then stay on to indicate that
the Factory Default Emergency Warning Flash Rate has been restored.
Order
Level Mode Default Patterns by Group - Synchronized
Light Head Group
Flash Rate
Front
Quad 75 FPM
Rear
Quad 75 FPM
L1 + L2
Front
Quad 75 FPM
Rear
Quad 75 FPM
Synchronized
Light Head Group
Front
Rear
TABLE 10
Light Head Group
Flash Sequence -
Synchronized
Sequence
1
Off
2
Left/Right
3
Even/Odd
TABLE 8
L1
L2
Quad 75 FPM
Quad 75 FPM
L1 + L3
Cycle
Cycle
TABLE 9
L3
Cycle
Cycle
L2 + L3
L1 + L2 + L3
Cycle
Cycle
Cycle
Cycle
Light Head Group Flash
Rates - Synchronized
Order
Flash Pattern
1
Double 75 FPM
2
Triple 75 FPM
3
Quad 75 FPM
4
Quint 75 FPM
5
Triple Pop 75 FPM
6
Quad Pop 75 FPM
7
Single 150 FPM
8
Double 150 FPM
9
Triple 150 FPM
10
Quad 150 FPM
11
Quint 150 FPM
12
Triple Pop 150 FPM
13
Quad Pop 150 FPM
14
Single 375 FPM
15
NFPA Qud 77 FPM
16
Cycle Flash
TABLE 11
Page 11 of 18