AC-power disturbance
• If AC power is disturbed or fails, the UPS continues to operate on battery power.
Button 6 flashesgreen.Innormalmode,theaudiblealarmbeepseverytenseconds,
then every three seconds when the end of battery backup time is near. In silent mode,
the audible alarm simply beeps once when the UPS transfers to battery power.
• If the power outage lasts longer than the battery backup time, the UPS shuts down
and automatically restarts when power is restored. Following a complete discharge, a
few hours are required to recharge the battery back to full backup time.
Surge protection:
All outlets include surge protection.
Shutdown of the battery backup outlets 19
Press button 6 for more than two seconds.

7. Troubleshooting

(For further information, visit the www.powerquality.eaton.com site or contact after-sales support.)
Problem
1
• The battery backup outlets
are not supplied with power.
2
• The connected devices are not
supplied when AC power fails.
3
• AC power is available, but the
UPS operates on battery power.
4
6
• Green button
flashesand
audible alarm beeps every 3
seconds.
5
• Fault sign
12
appear on the LCD
panel and audible alarm beeps
continuously.
6
8
• Green LED
is off and the
18
filteredoutlets
are supplied.
7
• EcoControl outlets keep powered
when main application (Master
outlet) is stopped.
Diagnostic
19
• Button
6
is not lighted on.
• The devices are not connected
to the battery backup outlets
• Circuit breaker
20
the rear of the UPS, has been
tripped by an overload on the
UPS output.
• The UPS battery backup outlets
19
are overloaded.
• A fault has occurred on the UPS.
The battery backup outlets
no longer supplied.
• Surge protection is no longer
provided.
• EcoControl function is not
activated or not properly set.
Solution
• Press button
it turns green.
• Connect the devices to the
19
.
battery backup outlets
• Disconnect excess equipment
, located at
and reset the circuit breaker
by pressing the corresponding
button.
• Disconnect excess equipment
connected to the battery backup
19
outlets
• Call after-sales support.
19
are
• Call after-sales support.
• Activate or set properly
EcoControl function using the
software provided with the
product.
6
and check that
19
.
20
.
9