Eaton Pulsar Series Installation And User Manual
Eaton Pulsar Series Installation And User Manual

Eaton Pulsar Series Installation And User Manual

Scalade up to 20kva
Hide thumbs Also See for Pulsar Series:

Advertisement

Quick Links

w w w . e a t o n . c o m
MX Frame
Scalade Up To 20kVA
Escalade hasta 20kVA
Installation and User Manual
Manual de instalción
y de usuario
Pulsar Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pulsar Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton Pulsar Series

  • Page 1 . e a t o n . c o m MX Frame Scalade Up To 20kVA Escalade hasta 20kVA Installation and User Manual Manual de instalción y de usuario Pulsar Series...
  • Page 3 Installation and User Manual Revision History MX Installation and User Manual, 86-87021-00 Revision: A00 ECN#: 005122 05/2007 Copyright © 2008 EATON All rights reserved. For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.eaton.com or call (800) 279-7776...
  • Page 5: Table Of Contents

    Contents Introduction ..........................3 IMPORTANT SAFETY INSTRUCTIONS ..................4 Symbol Usage ..........................5 1. Presentation MX 10U Frame Positions ....................7 MX 16U Frame Positions ....................8 10U Rear Panel ......................9 16U Rear Panel ......................10 Display and Control Panel ....................11 Extended Battery (EXB) ....................12 2. Installation Unpacking and Contents Check for 10U ..............13 Unpacking and Contents Check for 16U ..............14 Installation of Wheels and Leveling Feet (Shown for 16U Frame) ......15...
  • Page 6 Contents 5. Troubleshooting Troubleshooting LEDS (21) and (22) ................33 Troubleshooting Not Requiring EATON After-Sales Support ........33 Troubleshooting Requiring EATON After-Sales Support ..........34 6. Life Cycle Monitoring (LCM) Description .........................35 7. Maintenance Hot Swapping the Power Sub-Module ................37 Hot Swapping the Battery Sub-Module ...............37 8.
  • Page 7: Introduction

    Before installing MX Frame, please read the booklet on the required safety instructions. Then follow the indica- tions in this manual. To discover the entire range of EATON products and the options available for the MX range, we invite you to visit our web site at www.eaton.com or contact your EATON representative.
  • Page 8: Important Safety Instructions

    UPS recycling at the end of service life: ◗ EATON undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products ◗ recovered at the end of their service life (contact your EATON branch office).
  • Page 9: Symbol Usage

    Symbol Usage Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audible signal. LED off. LED on. 86-87021-00 A01 - Page 5...
  • Page 10 (This page left blank intentionally) 86-87021-00 A01 - Page 6...
  • Page 11: Presentation

    1. Presentation MX 10U Frame Positions Rack Mount 10U Rack Mount 10U (Without Wheels) Standard (With Wheels) Optional MX Frame 10U Weights and Dimensions MX 10U Empty MX 10U Frame MX 10U Frame Wheel Kit MX Power MX Battery Frame 5000 VA 10000 VA Sub-Module...
  • Page 12: Mx 16U Frame Positions

    MX 16U Frame Positions Rack Mount 16U Rack Mount 16U (Without Wheels) Standard (With Wheels) Optional MX Frame 16U Weights and Dimensions MX 16U Empty MX 16U Frame MX 16U Frame Wheel Kit MX Power MX Battery Frame 15000 VA 20000 VA Sub-Module Sub-Module...
  • Page 13: Rear Panel

    10U Rear Panel MX Frame (1) Manual Bypass switch (2) Slots 1 and 2 for optional communica- tion cards (3) Input switch (4) Connector for Remote Power Off control (RPO) (5) RS232 communication port (6) Connector for automatic detection of additional battery modules 1 through 2 (7) USB communication port (8) Communication port by relay...
  • Page 14: Rear Panel

    16U Rear Panel MX Frame (1) Manual Bypass switch (2) Slots 1 and 2 for optional communication cards (3) Input switch (4) Connector for Remote Power Off control (RPO) (5) RS232 communication port (6) Connector for automatic detection of additional battery modules 1 through 4 (7) USB communication port (8) Communication port by relay (9) DC connector for additional battery...
  • Page 15: Display And Control Panel

    Display and Control Panel (20) Load protected LED (21) Downgraded operation LED (22) Load not protected LED (23) Alphanumeric display (4 lines) (24) Escape (cancel) button LOAD PROTECTED (25) Function button (scroll down) 00.0kVA/000% LOADED (26) Function button (scroll up) ONLINE MODE 0+4 redundant (27) Enter (confirm) button...
  • Page 16: Extended Battery (Exb)

    Extended Battery (EXB) MX EXB RT (optional battery module) (11) Connectors for automatic detection of battery module(s) (12) Connectors for battery modules (to the UPS or to the other battery modules) (13) DC Battery circuit breaker MX Frame offers a standard backup time of 5 minutes at full load. To increase backup time, it is possible to connect MX EXB RT modules to the MX Frame.
  • Page 17: Installation

    2. Installation Unpacking and Contents Check for 10U MX 10U Frame Contents – Rack Mounting (87011) optional communication cards Sub-modules (87100) (87101) (41) MX Frame 10U (empty) (46) Screw driver (42) RS232 communications cable (47) Solution-Pac 2 power management suite CD-ROM (48) Network Management cards (optional) (43)
  • Page 18: Unpacking And Contents Check For 16U

    Unpacking and Contents Check for 16U MX 16U Frame Contents – Rack Mounting (87021) optional communication cards Sub-modules (87100) (87101) (40) MX Frame 16U (empty) (46) Screw driver (42) RS232 communications cable (47) Solution-Pac 2 power management suite CD-ROM (48) Network Management cards (optional) (43) Product documentation...
  • Page 19: Installation Of Wheels And Leveling Feet (Shown For 16U Frame)

    Installation of Wheels and Leveling Feet (Shown for 16U Frame) The battery sub-modules and power sub-modules must not be mounted yet. Do not install the UPS or battery module in a closed environment without air circulation. Follow steps 1 thru 6 for installation of wheels. 1.